arrow
返回

SOFC stack performance under high fuel utilization

delete2015-01-01
delete120
PRE
AI
Q
Qingping Fang *
L
L. Blum
R
Roland Peters
M
Murat Peksen
P
Peter Batfalsky
D
Detlef Stolten
DOI:10.1016/j.ijhydene.2014.11.094delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Based on previous long-term SOFC stack tests, two short stacks (one F20 and one F10 design) were tested in order to investigate stack performance under high fuel utilization (>40%) and possibly also high current densities (>0.5 Acm(-2)). The F20-design stack was still operated with relatively mild current densities (<= 0.5 Acm(-2)), but with high fuel utilization of up to 90% with 10% pre-reformed liquefied natural gas (LNG). The F10-design stack was operated with 20% humidified H-2, but with high fuel utilization of up to 90% and high current densities of up to 1.5 Acm(-2). Preliminary analysis shows that both F10- and F20-design stacks can be operated smoothly at a fuel utilization of similar to 85% in the temperature range of 750 similar to 800 degrees C, although an increase in concentration polarization can already be observed at the fuel utilization of similar to 80%. Operation with fuel utilization of 90% led to local oxidation of cells at a similar position in both stacks. Based on the calculations with a 1D model, such an effect was assumed to be due to the variation in fuel utilization caused by the temperature gradient in the cell. Copyright (C) 2014, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
Keyword:
SOFC
ASC stack
Fuel utilization
Temperature distribution
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

International Journal of Hydrogen Energy 封面图
International Journal of Hydrogen Energy
IF:
8.3
论文数:
5.5W
被引数:
23.1W

机构

R
research center julich
学者数:
9.9K
论文数: 6.7K
被引数: 10
H
Helmholtz Association
学者数:
13.2W
论文数: 10.7W
被引数: 145
引用论文

引用论文

err分享
err收藏
Performance Evaluation Technology for Long Term Durability and Reliability of SOFCs
err2013-10-06
err8
PREAI
errMugikura, Yoshihiro; Yasumoto, Kenji; Morita, Hiroshi; Yoshikawa, Masahiro; Yamamoto, Tohru
err分享
err收藏
CFY-stacks for use in stationary SOFC and SOEC applications
err2013-10-06
err10
PREAI
errMegel, Stefan; Dosch, Christian; Rothe, Stefan; Kusnezoff, Mihails; Trofimenko, Nikolai; Sauchuk, Viktar; Michaelis, Alexander; Bienert, Christian; Brandner, Marco; Venskutonis, Andreas; Kraussler, Wolfgang; Sigl, Lorenz S.
err分享
err收藏
Durability test and degradation behavior of a 2.5 kW SOFC stack with internal reforming of LNG
err2013-12-01
err75
PREAI
errFang, Qingping; Blum, Ludger; Batfalsky, Peter; Menzler, Norbert H.; Packbier, Ute; Stolten, Detlef
err分享
err收藏
Eneramic® Power Generator - A Reliable and Cycleable 100W SOFC System
err2013-10-06
err9
PREAI
errReuber, S.; Poenicke, A.; Wunderlich, C.; Michaelis, A.
err分享
err收藏
Long-term Operation of Planar Type SOFC Stacks
err2011-04-25
err25
PREAI
errde Haart, L. G. J.; Vinke, I. C.
err分享
err收藏
The effect of overpotentials on the transient response of the 300 W SOFC cell stack voltage
err2014-02-01
err50
PREAI
errKomatsu, Y.; Brus, G.; Kimijima, S.; Szmyd, J. S.
err分享
err收藏
没有更多内容