返回
Soft microflow sensors
DOI:10.1039/b813860e.png)
摘要
En 中文
We present a rapid prototyping method for integrating functional components in conventional PDMS microfluidic devices. We take advantage of stop-flow lithography (D. Dendukuri, S. S. Gu, D. C. Pregibon, T. A. Hatton and P. S. Doyle, Lab Chip, 2007, 7, 818)(1) to achieve the in situ fabrication of mobile and deformable elements with a controlled mechanical response. This strategy is applied to the fabrication of microflow sensors based on a deformable spring-like structure. We show that these sensors have a large dynamic range, typically 3 to 4 orders of magnitude, and that they can be scaled down to measure flows in the nl per min range. We prepared sensors with different geometries, and their flow-elongation characteristics were modeled with a simple hydrodynamic model, with good agreement between model and experiments.
Keyword:
FLOW LITHOGRAPHY
MICROFLUIDICS
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
L
IF:
5.4
论文数:
9.0K
被引数:
3.3W
机构
引用论文
Higher throughput and better particle resolution available - The shape of things to come
GREEN CHEMISTRY
IF9.2
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
LAB ON A CHIP
IF5.4
Using living radical polymerization to enable facile incorporation of materials in microfluidic cell culture devices
BIOMATERIALS