arrow
返回

Solid-State Detector SPECT Myocardial Perfusion Imaging

delete2019-08-02
delete56
delete
OA
AI
P
Piotr J. Slomka *
R
Robert J.H. Miller
L
Lien-Hsin Hu
G
Guido Germano
D
Daniel S. Berman
DOI:10.2967/jnumed.118.220657delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
There has been an evolutionary leap in SPECT imaging with the advent of camera systems that use solid-state crystals and novel collimator designs configured specifically for cardiac imaging. Solid-state SPECT camera systems have facilitated dramatic reductions in both imaging time and radiation dose while maintaining high diagnostic accuracy. These advances are related to simultaneous improvement in photon sensitivity due to the collimator and imaging geometry, as well as image resolution due to the improved energy resolution of the new crystals. Improved photon sensitivity has facilitated fast or low-dose myocardial perfusion imaging (MPI), and early dynamic imaging has emerged as a technique for assessing myocardial blood flow with SPECT. Lastly, general-purpose solid-state camera systems and hybrid SPECT/CT systems have also been developed that may have important clinical roles in cardiac imaging. This review summarizes state-of-the-art solid-state SPECT MPI technology and clinical applications, including emerging techniques for SPECT MPI flow estimation. We also discuss imaging protocols used with the new cameras, potential imaging pitfalls, and the latest data providing large-scale validation of the diagnostic and prognostic value of this new technology.
Keyword:
instrumentation
solid-state SPECT
SPECT MPI
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Journal of Nuclear Medicine 封面图
Journal of Nuclear Medicine
IF:
9.1
论文数:
6.2K
被引数:
3.0W

机构

C
Cedars Sinai Medical Center
学者数:
1.3W
论文数: 1.1W
被引数: 23
引用论文

引用论文

Diagnostic accuracy of cadmium-zinc-telluride-based myocardial perfusion SPECT: impact of attenuation correction using a co-registered external computed tomography
err2015-11-30
err27
errOAAI
errCaobelli, Federico; Akin, Muharrem; Thackeray, James T.; Brunkhorst, Thomas; Widder, Julian; Berding, Georg; Burchert, Ina; Bauersachs, Johann; Bengel, Frank M.
err分享
err收藏
Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation
err2010-01-27
err146
errOAAI
errBuechel, Ronny R.; Herzog, Bernhard A.; Husmann, Lars; Burger, Irene A.; Pazhenkottil, Aju P.; Treyer, Valerie; Valenta, Ines; von Schulthess, Patrick; Nkoulou, Rene; Wyss, Christophe A.; Kaufmann, Philipp A.
err分享
err收藏
Diagnostic Value of 13N-Ammonia Myocardial Perfusion PET: Added Value of Myocardial Flow Reserve
err2012-06-29
err173
errOAAI
errFiechter, Michael; Ghadri, Jelena R.; Gebhard, Catherine; Fuchs, Tobias A.; Pazhenkottil, Aju P.; Nkoulou, Rene N.; Herzog, Bernhard A.; Wyss, Christophe A.; Gaemperli, Oliver; Kaufmann, Philipp A.
err分享
err收藏
Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study
err2013-04-11
err172
errOAAI
errBen-Haim, Simona; Murthy, Venkatesh L.; Breault, Christopher; Allie, Rayjanah; Sitek, Arkadiusz; Roth, Nathaniel; Fantony, Jolene; Moore, Stephen C.; Park, Mi-Ae; Kijewski, Marie; Haroon, Athar; Slomka, Piotr; Erlandsson, Kjell; Baavour, Rafael; Zilberstien, Yoel; Bomanji, Jamshed; Di Carli, Marcelo F.
err分享
err收藏
Absolute myocardial blood flows derived by dynamic CZT scan vs invasive fractional flow reserve: Correlation and accuracy
err2021-02-01
err60
PREAI
errZavadovsky, Konstantin V.; Mochula, Andrew V.; Boshchenko, Alla A.; Vrublevsky, Alexander V.; Baev, Andrew E.; Krylov, Alexander L.; Gulya, Marina O.; Nesterov, Evgeny A.; Liga, Riccardo; Gimelli, Alessia
err分享
err收藏
学者 查看更多内容