Spatially regularized T1 estimation from variable flip angles MRI
DOI:10.1118/1.4722747.png)
摘要
En 中文
Purpose: To develop efficient algorithms for fast voxel-by-voxel quantification of tissue longitudinal relaxation time (T-1) from variable flip angles magnetic resonance images (MRI) to reduce voxel-level noise without blurring tissue edges. Methods: T-1 estimations regularized by total variation (TV) and quadratic penalty are developed to measure T-1 from fast variable flip angles MRI and to reduce voxel-level noise without decreasing the accuracy of the estimates. First, a quadratic surrogate for a log likelihood cost function of T-1 estimation is derived based upon the majorization principle, and then the TV-regularized surrogate function is optimized by the fast iterative shrinkage thresholding algorithm. A fast optimization algorithm for the quadratically regularized T-1 estimation is also presented. The proposed methods are evaluated by the simulated and experimental MR data. Results: The means of the T-1 values in the simulated brain data estimated by the conventional, TV-regularized, and quadratically regularized methods have less than 3% error from the true T-1 in both GM and WM tissues with image noise up to 9%. The relative standard deviations (SDs) of the T-1 values estimated by the conventional method are more than 12% and 15% when the images have 7% and 9% noise, respectively. In comparison, the TV-regularized and quadratically regularized methods are able to suppress the relative SDs of the estimated T-1 to be less than 2% and 3%, respectively, regardless of the image noise level. However, the quadratically regularized method tends to overblur the edges compared to the TV-regularized method. Conclusions: The spatially regularized methods improve quality of T-1 estimation from multiflip angles MRI. Quantification of dynamic contrast-enhanced MRI can benefit from the high quality measurement of native T-1. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4722747]
Keyword:
magnetic resonance imaging
variable flip angles
T-1 estimation
total variation
spatial regularization
dual approach
quadratic penalty
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
3.2
论文数:
3.7W
被引数:
3.2W
机构
引用论文
Determination of optimal angles for variable nutation proton magnetic spin-lattice, T1, and spin-spin, T2, relaxation times measurement确定可变章动质子磁自旋晶格T1和自旋自旋T2的最佳角度,弛豫时间测量
The effectiveness of Kampo medicines in the treatment of intractable acute, low-tone, sensorineural hearing loss汉方药物在治疗难治性急性、低频感音神经性听力损失中的有效性