Statistical validation based on parametric receiver operating characteristic analysis of continuous classification data
DOI:10.1016/S1076-6332(03)00538-5.png)
摘要
En 中文
Rationale and Objectives. The accuracy of diagnostic test and imaging segmentation is important in clinical practice because it has a direct impact on therapeutic planning. Statistical validations of classification accuracy was conducted based on parametric receiver operating characteristic analysis, illustrated on three radiologic examples. Materials and Methods. Two parametric models were developed for diagnostic or imaging data. Example 1: A semi-automated fractional segmentation algorithm was applied to magnetic resonance imaging of nine cases of brain tumors. The tumor and background pixel data were assumed to have bi-beta distributions. Fractional segmentation was validated against an estimated composite pixel-wise gold standard based on multi-reader manual segmentations. Example 2: The predictive value of 100 cases of spiral computed tomography of ureteral stone sizes, distributed as bi-normal after a non-linear transformation, under two treatment options received. Example 3: One hundred eighty cases had prostate-specific antigen levels measured in a prospective clinical trial. Radical prostatectomy was performed in all to provide a binary gold standard of local and advanced cancer stages. Prostate-specific antigen level was transformed and modeled by bi-normal distributions. In all examples, areas under the receiver operating characteristic curves were computed. Results. The areas under the receiver operating characteristic curves were: Example 1: Fractional segmentation of magnetic resonance imaging of brain tumors: meningiomas (0.924-0.984); astrocytomas (0.786-0.986); and other low-grade gliomas (0.896-0.983). Example 3: Ureteral stone size for treatment planning (0.813). Example 2: Prostate-specific antigen for staging prostate cancer (0.768). Conclusion. All clinical examples yielded fair to excellent accuracy. The validation metric area under the receiver operating characteristic curves may be generalized to evaluating the performances of several continuous classifiers related to imaging.
Keyword:
brain segmentation
magnetic resonance
prostate specific antigen (PSA)
genitourinary system
computed tomography
receiver operating characteristic (ROC) analysis
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
3.9
论文数:
8.8K
被引数:
1.0W
机构
暂无机构信息
引用论文
The influence of various precursors on solar-light-driven g-C3N4 synthesis and its effect on photocatalytic tetracycline hydrochloride (TCH) degradation各种前体对太阳光驱动的g-C3N4合成及其对光催化盐酸四环素 (TCH) 降解的影响
THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE受试者工作特征 (ROC) 曲线下面积的含义和用途
RADIOLOGY
IF15.2
Diagnosis and staging of ovarian cancer: Comparative values of Doppler and conventional US, CT, and MR imaging correlated with surgery and histopathologic analysis - Report of the Radiology Diagnostic Oncology Group
RADIOLOGY
IF15.2
Bayesian regression methodology for estimating a receiver operating characteristic curve with two radiologic applications: Prostate biopsy and spiral CT of ureteral stones
ACADEMIC RADIOLOGY
IF3.9