arrow
返回

Structured Reporting in Multiple Sclerosis Reduces Interpretation Time

delete2021-12-01
delete9
PRE
AI
J
Jonathan Lee *
R
Robert A Bermel
J
Jennifer Bullen
P
Paul Ruggieri
S
Stephen E. Jones
DOI:10.1016/j.acra.2020.08.006delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Rationale and Objectives: Previous studies have reported mixed results regarding whether the use of structured reporting (SR) leads to a change in interpretation times. The objective of this study was to quantify any change in interpretation times after the implementation of SR for multiple sclerosis (MS) follow-up magnetic resonance imaging (MRI) of the brain. Materials and Methods: Interpretation times before and after the transition to MS MRI SR were compared over a 5-year period. To control for changing practice patterns, a control group of non-MS (intracranial masses) reports not using SR was also assessed. In a secondary analysis, interpretation times for 2D and 3D MRI MS protocols after the initiation of SR were compared to determine whether increased image number with the 3D protocol affected interpretation times. Results: Mean and median interpretation times before the initiation of SR for MS MRI were 11.0 and 8.0 minutes versus 8.5 and 6.0 minutes after the implementation of SR (p < 0.001). Although non-MS MRI interpretation times also decreased, an interaction analysis demonstrated that the decrease in MS interpretation times was significantly higher (p < 0.001). Mean and median interpretation times using 3D protocols were slighter increased compared to interpretation times with 2D protocols (p = 0.036). Conclusion: After the implementation of SR for MS follow-up MRI at our institution, interpretation times significantly decreased despite the increased number of images with some of the examinations due to the adoption of 3D protocols. The adoption of SR for MS MRI follow-up scans may improve radiologist efficiency.
Keyword:
Reporting times
Interpretation times
Multiple Sclerosis (MS)
Structured reporting (SR)
Magnetic resonance imaging (MRI)
Multiple Sclerosis Partners Advancing Technology and Health Solutions (MS PATHS)
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Academic Radiology 封面图
Academic Radiology
IF:
3.9
论文数:
8.7K
被引数:
1.0W

机构

C
cleveland clinic foundation
学者数:
3.7W
论文数: 3.0W
被引数: 29
引用论文

引用论文

Is Structured Reporting the Answer?
errRADIOLOGY
IF15.2
err2014-10-01
err38
PREAI
errGunderman, Richard B.; McNeive, Logan R.
err分享
err收藏
err分享
err收藏
Various Expression Patterns of α1 and α2 Genes in IgA Deficiency
err2009-01-01
err0
errOAAI
errHiroko Suzuki; Hideo Kaneko; Toshiyuki Fukao; Rong Jin; Norio Kawamoto; Tsutomu Asano; Eiko Matsui; Kimiko Kasahara; Naomi Kondo
err分享
err收藏
Impact of a Structured Report Template on the Quality of CT and MRI Reports for Hepatocellular Carcinoma Diagnosis
err2017-09-01
err57
PREAI
errFlusberg, Milana; Ganeles, Jeremy; Ekinci, Tulay; Goldberg-Stein, Shlomit; Paroder, Viktoriya; Kobi, Mariya; Chernyak, Victoria
err分享
err收藏
Improving Communication of Diagnostic Radiology Findings through Structured Reporting
errRADIOLOGY
IF15.2
err2011-07-01
err350
errOAAI
errSchwartz, Lawrence H.; Panicek, David M.; Berk, Alexandra R.; Li, Yuelin; Hricak, Hedvig
err分享
err收藏
Atomic layer deposition of HfO2 on graphene from HfCl4 and H2O
err2011-02-20
err0
errOAAI
errHarry Alles; Jaan Aarik; Aleks Aidla; Aurelien Fay; Jekaterina Kozlova; Ahti Niilisk; Martti Pärs; Mihkel Rähn; Maciej Wiesner; Pertti Hakonen; Väino Sammelselg
err分享
err收藏
学者 查看更多内容