Successful pacing using a batteryless sunlight-powered pacemaker

delete2014-06-10
delete62
delete
OA
AI
A
Andreas Haeberlin *
A
Adrian Zurbuchen
J
Jakob Schaerer
J
Joerg Wagner
S
Sébastien Walpen
C
Christoph Huber
H
H. Haeberlin
J
Juerg Fuhrer
R
Rolf Vogel
DOI:10.1093/europace/euu127delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Aims Today's cardiac pacemakers are powered by batteries with limited energy capacity. As the battery's lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications. Thus, a pace-maker without primary batteries is desirable. The goal of this study was to test whether transcutaneous solar light could power a pacemaker. Methods and results We used a three-step approach to investigate the feasibility of sunlight-powered cardiac pacing. First, the harvestable power was estimated. Theoretically, a subcutaneously implanted 1 cm(2) solar module may harvest similar to 2500 mu W from sunlight (3 mm implantation depth). Secondly, ex vivo measurements were performed with solar cells placed under pig skin flaps exposed to a solar simulator and real sunlight. Ex vivo measurements under real sunlight resulted in a median output power of 4941 mu W/cm(2) [interquartile range (IQR) 3767-5598 mu W/cm(2), median skin flap thickness 3.0 mm (IQR 2.7-3.3 mm)]. The outputpower strongly depended on implantation depth (rho(Spearman) = -0.86, P < 0.001). Finally, a batteryless single-chamber pacemaker powered by a 3.24 cm(2) solar module was implanted in vivo in a pig to measure output power and to pace. In vivo measurements showed a median output power of >3500 mu W/cm(2) (skin flap thickness 2.8-3.84 mm). Successful batteryless VVI pacing using a subcutaneously implanted solar module was performed. Conclusion Based on our results, we estimate that a few minutes of direct sunlight (irradiating an implanted solar module) allow powering a pacemaker for 24 h using a suitable energy storage. Thus, powering a pacemaker by sunlight is feasible and may be an alternative energy supply for tomorrow's pacemakers.
Keyword:
Pacemaker
Pacing
Batteryless pacemaker
Energy harvesting
Solar pacemaker
Electrophysiology
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

E
Europace
IF:
7.4
论文数:
7.8K
被引数:
1.6W

机构

U
University of Bern
学者数:
862
论文数: 322
被引数: 0
引用论文

引用论文

Robust Optimization for Virtual Power Plants
err2017-11-07
err0
PREAI
errAllegra De Filippo; Michele Lombardi; Michela Milano; Alberto Borghetti
err分享
err收藏
A very low-power CMOS mixed-signal IC for implantable pacemaker applications
err2004-12-01
err296
PREAI
errWong, LSY; Hossain, S; Ta, A; Edvinsson, J; Rivas, DH; Nääs, H
err分享
err收藏
err
IF0
err
err0
PREAI
err
err分享
err收藏
Design and realization of an energy harvester using pulsating arterial pressure
err2013-09-01
err35
PREAI
errPfenniger, Alois; Wickramarathna, Lalith N.; Vogel, Rolf; Koch, Volker M.
err分享
err收藏
A Photo-Thermal-Electrical Converter Based On Carbon Nanotubes for Bioelectronic Applications
err2011-10-26
err46
PREAI
errMiyako, Eijiro; Hosokawa, Chie; Kojima, Masami; Yudasaka, Masako; Funahashi, Ryoji; Oishi, Isao; Hagihara, Yoshihisa; Shichiri, Mototada; Takashima, Mizuki; Nishio, Keiko; Yoshida, Yasukazu
err分享
err收藏
Ketofol in electroconvulsive therapy anesthesia: two stones for one bird
err2012-05-24
err0
PREAI
errSaban Yalcin; Harun Aydoğan; Salih Selek; Ahmet Kucuk; Hasan Husnu Yuce; Fatih Karababa; Tekin Bilgiç
err分享
err收藏
Structure and packing of aminoxyl and piperidinyl acrylamide monomers
err2015-09-18
err0
PREAI
errShailesh K. Goswami; Lyall R. Hanton; C. John McAdam; Stephen C. Moratti; Jim Simpson
err分享
err收藏
学者 查看更多内容