arrow
返回

Supervised and penalized baseline correction

delete2024-10-01
delete0
delete
OA
AI
E
Erik Andries *
R
Ramin Nikzad‐Langerodi
DOI:10.1016/j.chemolab.2024.105200delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Spectroscopic measurements can show distorted spectral shapes arising from a mixture of absorbing and scattering contributions. These distortions (or baselines) often manifest themselves as non-constant offsets or low-frequency oscillations. As a result, these baselines can adversely affect analytical and quantitative results. Baseline correction is an umbrella term where one applies pre-processing methods to obtain baseline spectra (the unwanted distortions) and then remove the distortions by differencing. However, current state- of-the art baseline correction methods do not utilize analyte concentrations even if they are available, or even if they contribute significantly to the observed spectral variability. We modify a class of state-of-the-art methods ( penalized baseline correction) ) that easily admit the incorporation of a priori analyte concentrations such that predictions can be enhanced. This modified approach will be deemed supervised and penalized baseline correction (SPBC). Performance will be assessed on two near infrared data sets across both classical penalized baseline correction methods (without analyte information) and modified penalized baseline correction methods (leveraging analyte information). There are cases of SPBC that provide useful baseline-corrected signals such that they outperform state-of-the-art penalized baseline correction algorithms such as AIRPLS. In particular, we observe that performance is conditional on the correlation between separate analytes: the analyte used for baseline correlation and the analyte used for prediction-the greater the correlation between the analyte used for baseline correlation and the analyte used for prediction, the better the prediction performance.
Keyword:
Baseline correction
Penalty terms
Alternating least squares
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Chemometrics and Intelligent Laboratory Systems 封面图
Chemometrics and Intelligent Laboratory Systems
IF:
3.8
论文数:
4.6K
被引数:
1.2W

机构

U
university of new mexico
学者数:
1.6W
论文数: 1.3W
被引数: 25
引用论文

引用论文

err分享
err收藏
HYPOGLYCAEMIA INDUCED BY CIBENZOLINE
err1988-05-01
err0
PREAI
errClaude Jeandel; MarieAnge Preiss; Henri Pierson; Francis Penin; Gerard Cuny; Bernard Bannwarth; Patrick Netter
err分享
err收藏
err分享
err收藏
Minimising contributions from scattering in infrared spectra by means of an integrating sphere
errANALYST
IF3.3
err2013-01-01
err51
errOAAI
errDazzi, Alexandre; Deniset-Besseau, Ariane; Lasch, Peter
err分享
err收藏
Baseline correction using adaptive iteratively reweighted penalized least squares
errANALYST
IF3.3
err2010-01-01
err902
PREAI
errZhang, Zhi-Min; Chen, Shan; Liang, Yi-Zeng
err分享
err收藏
A perfect smoother
err2003-05-30
err1.1K
PREAI
errEilers, PHC
err分享
err收藏
Baseline correction using asymmetrically reweighted penalized least squares smoothing
errANALYST
IF3.3
err2015-01-01
err334
PREAI
errBaek, Sung-June; Park, Aaron; Ahn, Young-Jin; Choo, Jaebum
err分享
err收藏
学者 查看更多内容