arrow
返回

Symmetric cell for improving solid-contact pH electrodes

delete2023-01-01
delete7
delete
OA
AI
E
Elena Zdrachek
T
Tara Forrest
E
Eric Bakker *
DOI:10.1016/j.aca.2022.340652delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Traditional pH glass electrodes are designed in a symmetrical manner to guarantee the most reliable and reproducible potentiometric measurements possible. Solid-contact and other pH probes not based on glass membranes are desirable because they allow for new types of applications, may be mass fabricated and less prone to breakage. Unfortunately, however, they introduce electrochemical asymmetry because the reference element used in the reference electrode compartment is now different. This work shows how symmetry may be restored with solid-contact pH probes, using a H+-selective ionophore-based polymeric membrane deposited on top of a conductive polymer (PEDOT-C14) as a transducer layer. The new cell implements a reference element that is composed of a similarly formulated pH probe immersed into a buffer solution and an Ag/AgCl element directly connected to a single-junction Ag/AgCl/3.0 M KCl reference electrode that is placed in contact with the sample solution. By implementing this design, the zero point of the solid-contact pH sensing system may be shifted to the conventional value of pH 7.0. The value of the zero point was experimentally confirmed as 6.96 +/- 0.02 pH units at three different temperatures in the range from 5 to 25 degrees C. This symmetric solid-contact potentiometric cell gave a long-term potential drift of 48 +/- 16 mu V h-1, comparable to that of a combination pH glass electrode.
Keyword:
H plus -selective solid-contact electrodes
H plus -selective ionophore
Conductive polymer
PEDOT-C14
Zero point
Symmetry
Temperature dependence
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Analytica Chimica Acta 封面图
Analytica Chimica Acta
IF:
6
论文数:
3.3W
被引数:
6.1W

机构

U
university of geneva
学者数:
3.6W
论文数: 2.9W
被引数: 35
引用论文

引用论文

Titanium dioxide nanoparticles: synthesis, characterisations and aquatic ecotoxicity effects
err2018-01-23
err0
PREAI
errAmine Mezni; Samir Alghool; Badreddine Sellami; Nesrine Ben Saber; Tariq Altalhi
err分享
err收藏
err
IF0
err
err0
PREAI
err
err分享
err收藏
err分享
err收藏
Iridium oxide pH sensor for biomedical applications. Case urea-urease in real urine samples
err2013-01-01
err115
PREAI
errPrats-Alfonso, Elisabet; Abad, Llibertat; Casan-Pastor, Nieves; Gonzalo-Ruiz, Javier; Baldrich, Eva
err分享
err收藏
Materials for violin bows
err2013-06-11
err0
PREAI
errUlrike G. K. Wegst; Stefan Oberhoff; Manfred Weller; Michael F. Ashby
err分享
err收藏
学者 查看更多内容