arrow
返回

Task-Specific Stimulation Duration for fNIRS Brain-Computer Interface

delete2020-01-01
delete23
delete
OA
AI
M
M. N. Afzal Khan
M
M. Raheel Bhutta
K
Keum‐Shik Hong *
DOI:10.1109/ACCESS.2020.2993620delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
In this paper, the most effective stimulation durations in the visual, somatosensory, and motor cortices are investigated. To evoke hemodynamic responses (HRs) for the purpose of brain-computer interface (BCI) with functional near-infrared spectroscopy (fNIRS), the best and the minimal durations for three tasks (visual, tapping, and poking) are presented. The examined tasks include the checkerboard, right-hand-index-finger poking, and the right-hand-index-finger tapping tasks in association with the visual, somatosensory, and motor cortices. Upon stimulations, the peak value, time to peak, and the full width at half maximum of the HRs are examined. Six different stimuli durations (i.e., 1, 3, 5, 7, 10 and 15 sec) were tested. Ten male subjects participated in the experiment. Three types of stimulations having the same duration were presented to the subjects randomly. The stimulation durations that showed the maximum peak values in the checkerboard, poking, and tapping tasks were 7, 5, and 10 sec, respectively. The peak value increased with the increase of stimulation duration. But beyond a certain period of time, the peak value did not increase anymore and sometimes it decreased when the stimulation period is too long. It is noted that 1-sec stimulation (for all three tasks) can generate a noticeable peak value. Instead, the initial dip upon poking occurred only with 1-sec poking (i.e., initial dip did not occur in all other poking periods). Conclusively, this work reveals the possibility of a BCI command generation within 1 sec.
Keyword:
Task analysis
Visualization
Brain-computer interfaces
Electroencephalography
Functional magnetic resonance imaging
Spatial resolution
Fingers
Brain-computer interface (BCI)
stimulation duration
functional near-infrared spectroscopy (fNIRS)
hemodynamic response
initial dip
poking
checkerboard
tapping
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

IEEE Access 封面图
IEEE Access
IF:
3.6
论文数:
9.8W
被引数:
29.4W

机构

S
Sejong University
学者数:
8.3K
论文数: 1.1W
被引数: 1.5W
P
pusan national university
学者数:
2.1W
论文数: 1.9W
被引数: 20
引用论文

引用论文

Ultra-fast, highly efficient and green synthesis of bioactive forsterite nanopowder via microwave irradiation
err2018-11-01
err0
PREAI
errMehdi Kheradmandfard; Seyed Farshid Kashani-Bozorg; Amir Hosein Noori-Alfesharaki; Anoushe Zargar Kharazi; Mansooreh Kheradmandfard; Narges Abutalebi
err分享
err收藏
Enhanced Drowsiness Detection Using Deep Learning: An fNIRS Study
err2019-01-01
err55
errOAAI
errTanveer, M. Asjid; Khan, M. Jawad; Qureshi, M. Jahangir; Naseer, Noman; Hong, Keum-Shik
err分享
err收藏
On the Secrecy Capacity of Block Fading Channels With a Hybrid Adversary
err2015-03-01
err0
errOAAI
errYuksel Ozan Basciftci; Onur Gungor; Can Emre Koksal; Fusun Ozguner
err分享
err收藏
Localization of Hemodynamic Responses to Simple Visual Stimulation: An fNIRS Study
err2012-04-30
err34
errOAAI
errWijeakumar, Sobanawartiny; Shahani, Uma; Simpson, William A.; McCulloch, Daphne L.
err分享
err收藏
学者 查看更多内容