Technical Note: On the spatial correlation between robust CT-ventilation methods and SPECT ventilation

delete2020-10-17
delete8
delete
OA
AI
E
Edward Castillo *
R
Richard Castillo
Y
Yevgeniy Vinogradskiy
G
Girish B. Nair
I
Inga S. Grills
T
Thomas Guerrero
C
Craig Stevens
DOI:10.1002/mp.14511delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Purpose The computed tomography (CT)-derived ventilation imaging methodology employs deformable image registration (DIR) to recover respiratory motion-induced volume changes from an inhale/exhale CT image pair, as a surrogate for ventilation. The Integrated Jacobian Formulation (IJF) and Mass Conserving Volume Change (MCVC) numerical methods for volume change estimation represent two classes of ventilation methods, namely transformation based and intensity (Hounsfield Unit) based, respectively. Both the IJF and MCVC methods utilize subregional volume change measurements that satisfy a specified uncertainty tolerance. In previous publications, the ventilation images resulting from this numerical strategy demonstrated robustness to DIR variations. However, the reduced measurement uncertainty comes at the expense of measurement resolution. The purpose of this study was to examine the spatial correlation between robust CT-ventilation images and single photon emission CT-ventilation (SPECT-V). Methods Previously described implementations of IJF and MCVC require the solution of a large scale, constrained linear least squares problem defined by a series of robust subregional volume change measurements. We introduce a simpler parameterized implementation that reduces the number of unknowns while increasing the number of data points in the resulting least squares problem. A parameter sweep of the measurement uncertainty tolerance,tau, was conducted using the 4DCT and SPECT-V images acquired for 15 non-small cell lung cancer patients prior to radiotherapy. For each test case, MCVC and IJF CT-ventilation images were created for 30 different uncertainty parameter values, uniformly sampled from the range0.01,0.25. Voxel-wise Spearman correlation between the SPECT-V and the resulting CT-ventilation images was computed. Results The median correlations between MCVC and SPECT-V ranged from 0.20 to 0.48 across the parameter sweep, while the median correlations for IJF and SPECT-V ranged between 0.79 and 0.82. For the optimal IJF tolerance tau=0.07, the IJF and SPECT-V correlations across all 15 test cases ranged between 0.12 and 0.90. For the optimal MCVC tolerance tau=0.03, the MCVC and SPECT-V correlations across all 15 test cases ranged between -0.06 and 0.84. Conclusion The reported correlations indicate that robust methods generate ventilation images that are spatially consistent with SPECT-V, with the transformation-based IJF method yielding higher correlations than those previously reported in the literature. For both methods, overall correlations were found to marginally vary for tau is an element of[0.03,0.15], indicating that the clinical utility of both methods is robust to both uncertainty tolerance and DIR solution.
Keyword:
4DCT
computed tomography
deformable image registration
SPECT
ventilation
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

University of Colorado System 封面图
University of Colorado System
学者数:
6.3W
论文数: 5.5W
被引数: 1.8K
B
beaumont health
学者数:
2.8K
论文数: 2.2K
被引数: 0
E
Emory University
学者数:
5.0W
论文数: 4.2W
被引数: 5.7W
U
University of Colorado Denver
学者数:
5.3K
论文数: 4.2K
被引数: 10
学者 查看更多机构
引用论文

引用论文

Estimation of Large Motion in Lung CT by Integrating Regularized Keypoint Correspondences into Dense Deformable Registration
err2017-08-01
err82
errOAAI
errRuehaak, Jan; Polzin, Thomas; Heldmann, Stefan; Simpson, Ivor J. A.; Handels, Heinz; Modersitzki, Jan; Heinrich, Mattias P.
err分享
err收藏
Quantification of regional ventilation from treatment planning CT
err2005-07-01
err158
PREAI
errGuerrero, T; Sanders, K; Noyola-Martinez, J; Castillo, E; Zhang, Y; Tapia, R; Guerra, R; Borghero, Y; Komaki, R
err分享
err收藏
Estimating lung ventilation directly from 4D CT Hounsfield unit values
err2015-12-17
err48
errOAAI
errKipritidis, John; Hofman, Michael S.; Siva, Shankar; Callahan, Jason; Le Roux, Pierre-Yves; Woodruff, Henry C.; Counter, William B.; Keall, Paul J.
err分享
err收藏
Robust CT ventilation from the integral formulation of the Jacobian
err2019-03-22
err36
errOAAI
errCastillo, Edward; Castillo, Richard; Vinogradskiy, Yevgeniy; Dougherty, Michele; Solis, David; Myziuk, Nicholas; Thompson, Andrew; Guerra, Rudy; Nair, Girish; Guerrero, Thomas
err分享
err收藏
Technical Note: Deriving ventilation imaging from 4DCT by deep convolutional neural network
err2019-03-12
err28
errOAAI
errZhong, Yuncheng; Vinogradskiy, Yevgeniy; Chen, Liyuan; Myziuk, Nick; Castillo, Richard; Castillo, Edward; Guerrero, Thomas; Jiang, Steve; Wang, Jing
err分享
err收藏
Pulmonary blood mass dynamics on 4DCT during tidal breathing
err2019-02-18
err10
PREAI
errMyziukh, Nicholas; Guerrero, Thomas; Sakthivel, Gukan; Solis, David, Jr.; Nair, Girish; Guerra, Rudy; Castillo, Edward, Jr.
err分享
err收藏
Effects of several species of human leukocyte interferon on cytotoxic activity of NK cells and monocytes
err2006-07-17
err0
PREAI
errJohn R. Ortaldo; Alberto Mantovani; Donna Hobbs; Menachem Rubinstein; Sidney Pestka; Ronald B. Herberman
err分享
err收藏
err分享
err收藏
Dynamic ventilation imaging from four-dimensional computed tomography
err2006-01-25
err232
PREAI
errGuerrero, T; Sanders, K; Castillo, E; Zhang, Y; Bidaut, L; Pan, TS; Komaki, R
err分享
err收藏
学者 查看更多内容