arrow
返回

Technical Note: SCUDA: A software platform for cumulative dose assessment

delete2016-09-06
delete3
delete
OA
AI
S
Seyoun Park
T
Todd McNutt
W
William Plishker
H
Harry Quon
J
John Wong
R
Raj Shekhar *
J
Junghoon Lee *
DOI:10.1118/1.4961985delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Purpose: Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for Cumulative Dose Assessment (SCUDA) that can be seamlessly integrated into the clinical workflow. Methods: SCUDA consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our image PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. Results: The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 +/- 5.0 Gy (mean +/- STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. Conclusions: The authors developed a unified software platform that provides accurate and efficient monitoring of anatomical changes and computation of actually delivered dose to the patient, thus realizing an efficient cumulative dose computation workflow. Evaluation on HN cases demonstrated the utility of our platform for monitoring the treatment quality and detecting significant dosimetric variations that are keys to successful ART. (C) 2016 American Association of Physicists in Medicine.
Keyword:
software platform
adaptive radiotherapy
deformable registration
segmentation
dose computation
graphics processing unit
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

C
children's national health system
学者数:
5.7K
论文数: 4.3K
被引数: 4
J
Johns Hopkins University
学者数:
10.2W
论文数: 8.8W
被引数: 13.0W
引用论文

引用论文

err
IF0
err
err0
PREAI
err
err分享
err收藏
Improving the Generalisation Ability of Neural Networks Using a Lévy Flight Distribution Algorithm for Classification Problems
err2023-03-14
err0
PREAI
errEhsan Bojnordi; Seyed Jalaleddin Mousavirad; Mahdi Pedram; Gerald Schaefer; Diego Oliva
err分享
err收藏
Atrial natriuretic peptide induces acrosomal exocytosis of human spermatozoa
err1998-02-01
err0
errOAAI
errRonit Rotem; Nadav Zamir; Nurit Keynan; Dalit Barkan; Haim Breitbart; Zvi Naor
err分享
err收藏
Healthcare personnel infected with novel influenza A H1N1 virus in university hospitals in Buenos Aires, Argentina
err2010-09-21
err0
PREAI
errMarcia Querci; Martin E. Stryjewski; Fabián Herrera; Elena Temporiti; Wanda Alcalá; Natalia Chavez; Laura Figueras; Fernanda Barberis; Marcela Echavarría; Cristina Videla; Alfredo Martínez; Guadalupe Carballal; Pablo Bonvehí
err分享
err收藏
Impulsive moments at work
err2019-02-11
err0
errOAAI
errRichard Smith; Christophe Hyde; Terry Lee; Richard Almond
err分享
err收藏
err分享
err收藏
Real-time dose computation: GPU-accelerated source modeling and superposition/convolution
err2010-12-21
err54
PREAI
errJacques, Robert; Wong, John; Taylor, Russell; McNutt, Todd
err分享
err收藏
学者 查看更多内容