arrow
返回

Testing and modelling of a variable speed scroll compressor

delete2009-02-01
delete90
PRE
AI
C
Cristian Cuevas *
J
Jean Lebrun
DOI:10.1016/j.applthermaleng.2008.03.016delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Variable speed compressors offer continuous control, low noise level, reduced vibration, low-start current, rapid temperature control, by operating the compressor at higher speeds initially, and better COPs than the conventional on/off control. However, there exist some drawbacks concerning the inverter efficiency, the effect of the inverter on the induction motor and the effect of variable speed on the compressor isentropic and volumetric efficiencies. This study gives some experimental results as to inverter and compressor performances: it can be observed that the inverter efficiency varies between 95% and 98% for compressor electrical power varying between 1.5 and 6.5 kW : and that compressor efficiencies are not enormously influenced by compressor supply frequency, but depend mainly on compressor pressure ratio, except the tests developed at 35 Hz and one test at 40 Hz, for which the difference is attributed to the compressor internal leakages due to a lack of lubrication at low speeds. At 75 Hz there was also observed a slight degradation that can be attributed to the electromechanical losses that increase with compressor speed. A maximal isentropic efficiency of 0.65 for a pressure ratio of the order of 2.2 is obtained. The volumetric efficiency decreases linearly from 0.98 for a pressure ratio of 1.5 to 0.83 for a pressure ratio of 5.6. In spite of the test conditions (condensing and evaporating pressures up to 40 and 20 bar, respectively). the compressor performance stays unchanged. The experimental results obtained at 50 Hz are used to identify six parameters of a semi-empirical model which is then used to simulate the different tests developed at different compressor speeds. The simulated results are in very good agreement with those measured with averages errors of -0.5 K: +3 g s(-1) and -24 W for the exhaust temperature, the refrigerant flow rate and the compressor electrical power, respectively. The results show that motor losses induced by the inverter are negligible. (C) 2008 Elsevier Ltd. All rights reserved.
Keyword:
Scroll compressor
Variable speed
Testing
Modelling
Inverter efficiency
Isentropic efficiency
Volumetric efficiency
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Applied Thermal Engineering 封面图
Applied Thermal Engineering
IF:
6.9
论文数:
2.8W
被引数:
10.6W

机构

U
University of Liege
学者数:
1.7W
论文数: 1.4W
被引数: 2.1W
U
universidad de concepcion
学者数:
8.4K
论文数: 6.4K
被引数: 8
引用论文

引用论文

mtDNA variability determines spontaneous joint aging damage in a conplastic mouse model
err2022-07-02
err0
errOAAI
errMorena Scotece; Carlos Vaamonde-García; Ana Victoria Lechuga-Vieco; Alberto Centeno Cortés; María Concepción Jiménez Gómez; Purificación Filgueira-Fernández; Ignacio Rego-Pérez; José Antonio Enríquez; Francisco J. Blanco
err分享
err收藏
err分享
err收藏