The effect of calibration parameters on the control of a myoelectric hand prosthesis using EMG feedback

delete2021-06-22
delete21
delete
OA
AI
J
Jack Tchimino
M
Marko Marković
J
Jakob Lund Dideriksen
S
Strahinja Došen *
DOI:10.1088/1741-2552/ac07bedelete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Objective. The implementation of somatosensory feedback in upper limb myoelectric prostheses is an important step towards the restoration of lost sensory-motor functions. EMG feedback is a recently proposed method for closing the control loop wherein the myoelectric signal that drives the prosthesis is also used to generate the feedback provided to the user. Therefore, the characteristics of the myoelectric signal (variability and sensitivity) are likely to significantly affect the ability of the subject to utilize this feedback for online control of the prosthesis. Approach. In the present study, we investigated how the cutoff frequency of the low-pass filter (0.5, 1 and 1.5 Hz) and normalization value (20%, 40% and 60% of the maximum voluntary contraction (MVC)), that are used for the generation of the myoelectric signal, affect the quality of closed-loop control with EMG feedback. Lower cutoff and normalization decrease the intrinsic variability of the EMG but also increase the time lag between the contraction and the feedback (cutoff) as well as the sensitivity of the myoelectric signal (normalization). Ten participants were asked to generate three grasp force levels with a myoelectric prosthetic hand, while receiving five-level vibrotactile EMG feedback, over nine experimental runs (all parameter combinations). Main results. The outcome measure was the success rate (SR) in achieving the appropriate level of myoelectric signal (primary outcome) and grasping force (secondary outcome). Overall, the experiments demonstrated that EMG feedback provided robust control across conditions. Nevertheless, the performance was significantly better for the lowest cutoff (0.5 Hz) and higher normalization (40% and 60%). The highest SR for the EMG was 71.9%, achieved in the condition (40% MVC and 0.5 Hz), and this was 24.1% higher than that in the condition (20% MVC and 1.5 Hz), which resulted in the lowest performance. The SR for the force followed a similar trend. Significance. This is the first study that systematically explored the parameter space for the calibration of EMG feedback, which is a critical step for the future clinical application of this approach.
Keywords:
closed-loop control
somatosensory feedback
EMG feedback
vibrotactile stimulation
grasping force control
myoelectric prosthesis

Journal

Journal of Neural Engineering cover
Journal of Neural Engineering
IF:
3.8
Papers:
4.0K
Citations:
1.4W

Organization

U
University of Gottingen
Scholars:
2.5W
Papers: 2.1W
Citations: 36
A
aalborg university
Scholars:
1.5W
Papers: 1.7W
Citations: 22
Cited Papers

Cited Papers

Citing Papers

Citing Papers