arrow
返回

The sonopartogram

delete2023-05-01
delete6
PRE
AI
S
S. Usman
M
Mariya Kovalenko
W
Wassim A. Hassan
DOI:10.1016/j.ajog.2022.06.027delete
delete原文链接
delete分享
delete收藏
摘要

摘要

En 中文
The assessment of labor progress from digital vaginal examination has remained largely unchanged for at least a century, despite the current major advances in maternal and perinatal care. Although inconsistently reproducible, the findings from digital vaginal examination are customarily plotted manually on a partogram, which is composed of a graphical representation of labor, together with maternal and fetal observations. The partogram has been developed to aid recognition of failure to labor progress and guide management-specific obstetrical intervention. In the last decade, the use of ultrasound in the delivery room has increased with the advent of more powerful, portable ultrasound machines that have become more readily available for use. Although ultrasound in intrapartum practice is predominantly used for acute-management, an ultrasound-based partogram, a sonopartogram, might represent an objective tool for the graphical representation of labor. Demonstrating greater accuracy for fetal head position and more objectivity in the assessment of fetal head station, it could be considered complementary to traditional clinical assessment. The development of the sonopartogram concept would require further undertaking of serial measurements. Advocates of ultrasound will concede that its use has yet to demonstrate a difference in obstetrical and neonatal morbidity in the context of the management of labor and delivery. Taking a step beyond the descriptive graphical representation of labor progress is the question of whether a specific combination of clinical and demographic parameters might be used to inform knowledge of labor outcomes. Intrapartum cesarean deliveries and deliveries assisted by forceps and vacuum are all associated with a heightened risk of maternal and perinatal adverse outcomes. Although these outcomes cannot be precisely predicted, many known risk factors exist. Malposition and high station of the fetal head, short maternal stature, and other factors, such as caput succedaneum, are all implicated in operative delivery; however, the contribution of individual parameters based on clinical and ultrasound assessments has not been quantified. Individualized risk prediction models, including maternal characteristics and ultrasound findings, are increasingly used in women's health-for example, in preeclampsia or trisomy screening. Similarly, intrapartum cesarean delivery models have been developed with good prognostic ability in specifically selected populations. For intrapartum ultrasound to be of prognostic value, robust, externally validated prediction models for labor outcome would inform delivery management and allow shared decision-making with parents.
Keyword:
angle of progression
cervical dilatation
head descent
head-perineum distance
intrapartum ultrasound
partogram

期刊

American Journal of Obstetrics and Gynecology 封面图
American Journal of Obstetrics and Gynecology
IF:
8.4
论文数:
3.3W
被引数:
4.9W

机构

I
imperial college london
学者数:
3.2K
论文数: 1.2K
被引数: 2.5K
K
KU Leuven
学者数:
1.8K
论文数: 618
被引数: 1.6K
引用论文

引用论文

A Nonlinear Dynamical Systems‐Based Modeling Approach for Stochastic Simulation of Streamflow and Understanding Predictability
err2019-07-31
err0
PREAI
errBalaji Rajagopalan; Solomon Tassew Erkyihun; Upmanu Lall; Edith Zagona; Kenneth Nowak
err分享
err收藏
Investigating optimum ship route in the Antarctic in presence of sea ice and wind resistances – A case study between Bharati and Maitri
err2021-12-01
err0
errOAAI
errPoonam Mishra; Shivang Alok; D. Ram Rajak; Javed M. Beg; I.M. Bahuguna; Isha Talati
err分享
err收藏
3D‐Printed PCL/rGO Conductive Scaffolds for Peripheral Nerve Injury Repair3D打印PCL/rGO导电支架用于周围神经损伤修复
err2018-11-12
err0
PREAI
errSanjairaj Vijayavenkataraman; Siti Thaharah; Shuo Zhang; Wen Feng Lu; Jerry Ying Hsi Fuh
err分享
err收藏
学者 查看更多内容