返回
The Virgo automatic alignment system
DOI:10.1088/0264-9381/23/8/S13.png)
摘要
En 中文
The automatic alignment system of the Virgo interferometer differs substantially from those used in similar experiments, since it uses a variant of the Anderson technique. This implies a completely different control topology with respect to other detectors, and the main feature is a strong coupling of different degrees of freedom in the optical signals. It also provides two extra output ports in which differential wave-front sensors can be placed, namely the light transmitted by the Fabry-Perot arm cavities. We report on the first experimental demonstration of this technique on a large scale recycled interferometer, and on the present status of the automatic alignment system.
Keyword:
OPTICAL INTERFEROMETERS
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
3.7
论文数:
1.3W
被引数:
3.0W
机构
暂无机构信息
引用论文
Massed Refresh: An Energy-Efficient Technique to Reduce Refresh Overhead in Hybrid Memory Cube Architectures集中式刷新:一种在混合内存立方体架构中减少刷新开销的节能技术
A local control system for the test masses of the Virgo gravitational wave detector处女座引力波探测器测试质量的本地控制系统