arrow
返回

Three-Phase-Measurement-Based Load Modeling Technique Using Unbalanced Fault Data

delete2020-01-01
delete4
delete
OA
AI
S
Sangwook Han *
DOI:10.1109/ACCESS.2020.2992369delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
This study presents a load modeling technique using unsymmetrical fault data. Typically, three-phase balanced fault data are prerequisite for load modeling; however, the existing technique utilizes only positive sequence data. Obtaining symmetrical data from a real power system is very difficult as three-phase faults are very rare. In this study, I aimed to improve existing methods designed for estimating load parameters from three-phase symmetrical fault data via load modeling of unsymmetrical faults. The proposed method corrects the existing algorithm using positive sequence data along with three-phase data, namely phases-A, -B, and -C. The equation for each phase of the load model is obtained and subsequently used for load parameter estimation. The load model parameters are estimated using the data obtained from phases-A, -B, and -C, unlike in existing load models that use only positive sequence data. Unsymmetrical faults occur more frequently in a system than symmetrical faults, and numerous opportunities for load model parameter estimation are available. Applying this algorithm to the three-phase data collected using phasor measurement unit-like data acquisition devices is expected to considerably increase both the parameter estimation accuracy and frequency during load modeling parameter estimation in the future.
Keyword:
Load modeling
measurement-based approach
parameter estimation
three-phase data
unbalanced disturbances
asymmetrical fault
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

IEEE Access 封面图
IEEE Access
IF:
3.6
论文数:
9.8W
被引数:
29.4W

机构

暂无机构信息
引用论文

引用论文

Recognition of the Codon-Anticodon Helix by Ribosomal RNA
err1999-09-10
err0
PREAI
errSatoko Yoshizawa; Dominique Fourmy; Joseph D. Puglisi
err分享
err收藏
Measurement-Based Dynamic Load Modeling Using the Vector Fitting Technique
err2018-01-01
err61
PREAI
errKontis, Eleftherios O.; Papadopoulos, Theofilos A.; Chrysochos, Andreas I.; Papagiannis, Grigoris K.
err分享
err收藏
A three phase serpentine micro electrode array for AC electroosmotic flow pumping
err2010-06-12
err0
PREAI
errKongying Xie; Yongjun Lai; Xin Guo; Rob J. Campbell
err分享
err收藏
An Event-Oriented Method for Online Load Modeling Based on Synchrophasor Data
err2015-07-01
err57
PREAI
errGe, Yinyin; Flueck, Alexander J.; Kim, Dae-Kyeong; Ahn, Jong-Bo; Lee, Jae-Duck; Kwon, Dae-Yun
err分享
err收藏
err分享
err收藏
Improvement of Composite Load Modeling Based on Parameter Sensitivity and Dependency Analyses
err2014-01-01
err79
PREAI
errSon, SeoEun; Lee, Soo Hyoung; Choi, Dong-Hee; Song, Kyung-Bin; Park, Jung-Do; Kwon, Young-Hoon; Hur, Kyeon; Park, Jung-Wook
err分享
err收藏
学者 查看更多内容