arrow
返回

Tilted grating phase-contrast computed tomography using statistical iterative reconstruction

delete2018-04-26
delete4
delete
OA
AI
L
Lorenz Birnbacher *
M
Manuel Viermetz
W
Wolfgang Noichl
S
Sebastian Allner
A
Andreas Fehringer
M
Maximilian von Teuffenbach
M
Marian Willner
K
Klaus Achterhold
P
Peter B. Noël
T
Thomas Koehler
J
Julia Herzen
F
Franz Pfeiffer
DOI:10.1038/s41598-018-25075-7delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Grating-based phase-contrast computed tomography (GBPC-CT) enables increased soft tissue differentiation, but often suffers from streak artifacts when performing high-sensitivity GBPC-CT of biomedical samples. Current GBPC-CT setups consist of one-dimensional gratings and hence allow to measure only the differential phase-contrast (DPC) signal perpendicular to the direction of the grating lines. Having access to the full two-dimensional DPC signal can strongly reduce streak artefacts showing up as characteristic horizontal lines in the reconstructed images. GBPC-CT with gratings tilted by 45 degrees around the optical axis, combining opposed projections, and reconstructing with filtered backprojection is one method to retrieve the full three-dimensional DPC signal. This approach improves the quality of the tomographic data as already demonstrated at a synchrotron facility. However, additional processing and interpolation is necessary, and the approach fails when dealing with cone-beam geometry setups. In this work, we employ the tilted grating configuration with a laboratory GBPC-CT setup with cone-beam geometry and use statistical iterative reconstruction (SIR) with a forward model accounting for diagonal grating alignment. Our results show a strong reduction of streak artefacts and significant increase in image quality. In contrast to the prior approach our proposed method can be used in a laboratory environment due to its cone-beam compatibility.
Keyword:
QUANTITATIVE PHASE
INTERFEROMETER
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Scientific Reports 封面图
Scientific Reports
IF:
3.9
论文数:
28.2W
被引数:
83.5W

机构

T
Technical University of Munich
学者数:
5.2W
论文数: 3.9W
被引数: 6.2W
P
Philips Research
学者数:
1.4K
论文数: 1.0K
被引数: 0
引用论文

引用论文

Measurement of the nucleon structure functions
err1979-12-01
err0
PREAI
errB. A. Gordon; W. A. Loomis; F. M. Pipkin; S. H. Pordes; A. L. Sessoms; W. D. Shambroom; C. Tao; L. J. Verhey; Richard Wilson; H. L. Anderson; R. M. Fine; R. H. Heisterberg; W. W. Kinnison; H. S. Matis; L. W. Mo; L. C. Myrianthopoulos; S. C. Wright; W. R. Francis; R. G. Hicks; T. B. W. Kirk; T. W. Quirk; V. K. Bharadwaj; N. E. Booth; G. I. Kirkbride; J. Proudfoot; A. Skuja; M. A. Staton; W. S. C. Williams
err分享
err收藏
Quantitative phase-contrast tomography of a liquid phantom using a conventional x-ray tube source
err2009-05-29
err102
errOAAI
errHerzen, Julia; Donath, Tilman; Pfeiffer, Franz; Bunk, Oliver; Padeste, Celestino; Beckmann, Felix; Schreyer, Andreas; David, Christian
err分享
err收藏
err分享
err收藏
Experimental Realisation of High-sensitivity Laboratory X-ray Grating-based Phase-contrast Computed Tomography高灵敏度实验室x射线光栅相衬ct的实验实现
err2016-04-04
err63
errOAAI
errBirnbacher, Lorenz; Willner, Marian; Velroyen, Astrid; Marschner, Mathias; Hipp, Alexander; Meiser, Jan; Koch, Frieder; Schroeter, Tobias; Kunka, Danays; Mohr, Juergen; Pfeiffer, Franz; Herzen, Julia
err分享
err收藏
Single-shot x-ray differential phase-contrast and diffraction imaging using two-dimensional transmission gratings
err2010-06-03
err180
errOAAI
errWen, Harold H.; Bennett, Eric E.; Kopace, Rael; Stein, Ashley F.; Pai, Vinay
err分享
err收藏
X-ray phase imaging with a grating interferometer
err2005-08-08
err1.2K
errOAAI
errWeitkamp, T; Diaz, A; David, C; Pfeiffer, F; Stampanoni, M; Cloetens, P; Ziegler, E
err分享
err收藏
Investigation of discrete imaging models and iterative image reconstruction in differential X-ray phase-contrast tomography
err2012-04-25
err33
errOAAI
errXu, Qiaofeng; Sidky, Emil Y.; Pan, Xiaochuan; Stampanoni, Marco; Modregger, Peter; Anastasio, Mark A.
err分享
err收藏
Quantitative imaging of electron density and effective atomic number using phase contrast CT
err2010-04-19
err97
errOAAI
errQi, Zhihua; Zambelli, Joseph; Bevins, Nicholas; Chen, Guang-Hong
err分享
err收藏
Mobile markerless augmented reality and its application in forensic medicine移动无标记增强现实技术及其在法医学中的应用
err2014-08-23
err0
PREAI
errThomas Kilgus; Eric Heim; Sven Haase; Sabine Prüfer; Michael Müller; Alexander Seitel; Markus Fangerau; Tamara Wiebe; Justin Iszatt; Heinz-Peter Schlemmer; Joachim Hornegger; Kathrin Yen; Lena Maier-Hein
err分享
err收藏
学者 查看更多内容