返回
Topology optimization based deterministic lateral displacement array design for cell separation
DOI:10.1016/j.chroma.2022.463384.png)
摘要
En 中文
Circulating tumor cell (CTC) can be used to guide cancer theranostics. How to isolate efficiently CTCs from blood owns great clinical requirement. Deterministic lateral displacement (DLD) is a pillar-array-based effective passive microfluidic method to separate cells based on their sizes. DLD is a potential CTC isolation tool. Pillar shape is one of the key priorities in DLD array design. Altered zigzag mode is a normally undesired phenomenon that leads zigzag particles away from flow direction. This work makes use of the altered zigzag mode to manipulate zigzag particles for the first time, and developed a novel DLD chip with topology optimized pillar shape and a wide DLD channel. The novel designing method based on topology optimization (TO) greatly increases lateral displacement of different sized cells, meanwhile demonstrates its universality and expansibility. The proposed structure has the ability to shorten the device and to manipulate cells flexibly. Bead experiment has been applied to determine the critical diameter of the DLD array. Numerical, bead and cell experiment have been carried out to verify the separation efficiency of the structure. The TO-based wide DLD channel promotes the separation efficiency. (C) 2022 Published by Elsevier B.V.
Keyword:
Circulating tumor cell
Deterministic lateral displacement
Topology optimization
Pillar shape
Altered zigzag mode
期刊
IF:
4
论文数:
3.2W
被引数:
5.0W
机构
引用论文
3D deterministic lateral displacement (3D-DLD) cartridge system for high throughput particle sorting
Slanted, asymmetric microfluidic lattices as size-selective sieves for continuous particle/cell sorting
LAB ON A CHIP
IF5.4
An integrated microfluidic device for rapid and high-sensitivity analysis of circulating tumor cells
SCIENTIFIC REPORTS
IF3.9