arrow
返回

Tumor microenvironment-responsive touch sensor-based pH-triggered controllable conductive hydrogel

delete2021-12-01
delete23
PRE
AI
A
Akhmad Irhas Robby
S
Seul Gi Kim
H
Hyeong Jun Jo
G
Gibaek Lee
K
Kang Dae Lee *
J
Ji Hyun Ryu *
S
Sung Young Park *
DOI:10.1016/j.apmt.2021.101259delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
A tumor microenvironment-responsive wireless strain-pressure hydrogel sensor based on pH-induced controllable nanoparticles was designed for cancer detection in vitro in vivo model, with excellent ability to distinguish between cancer and normal cells. The pH-responsive nanoparticles (CD-PNB), comprising diol-diol crosslinked semiconducting carbon dots (CDs) and non-conductive polymer (PNB), are sensitive to acidic tumor microenvironments and play crucial role in demonstrating tumor-selective strain-pressure responses. Upon application of strain and pressure, CD-PNB@PVA hydrogel produced distinct electronic signals in the presence of cancer cells (HeLa, PC-3), exhibiting higher strain-pressure sensitivity compared to the normal cells (MDCK, CHO-K1). The strain and pressure gage factors for cancer-cell-treated CD-PNB@PVA hydrogel were found to be 0.7439 and 5.3052 kPa(-1), which were higher than normal-celltreated CD-PNB@PVA hydrogel (0.5009 and 4.2720 kPa(-1)). CD-PNB@PVA hydrogel demonstrated excellent response in tumor-bearing mice based on in situ and ex situ measurements, with no inflammation during hydrogel implantation. Moreover, wireless sensing system was used along with CD-PNB@PVA hydrogel to simplify monitoring process and obtain real-time conductivity and strain-pressure profiles on smartphone. Thus, this approach constructs a tumor microenvironment-responsive strain-pressure hydrogel sensor and presents potential for sensitive and selective tumor detection in point-of-care diagnostic applications. (C) 2021 Elsevier Ltd. All rights reserved.
Keyword:
Carbon dot
pH-responsive
Pressure sensing
Electroconductive hydrogel
Wireless sensor

期刊

Applied Materials Today 封面图
Applied Materials Today
IF:
6.9
论文数:
3.4K
被引数:
1.6W

机构

W
Wonkwang University
学者数:
3.2K
论文数: 2.9K
被引数: 2.2K
K
Korea National University of Transportation
学者数:
1.2K
论文数: 1.3K
被引数: 1.5K
引用论文

引用论文

NIR-vis-Induced pH-Sensitive TiO2 Immobilized Carbon Dot for Controllable Membrane-Nuclei Targeting and Photothermal Therapy of Cancer Cells
err2020-07-28
err38
PREAI
errPhuong, Pham Thi My; Won, Hyun Jeong; Robby, Akhmad Irhas; Kim, Seul Gi; Im, Gwang-Bum; Bhang, Suk Ho; Lee, Gibaek; Park, Sung Young
err分享
err收藏
err分享
err收藏
Flexible and self-healing electrochemical hydrogel sensor with high efficiency toward glucose monitoring
err2020-05-01
err82
PREAI
errLiang, Zhen; Zhang, Jieyu; Wu, Can; Hu, Xuefeng; Lu, Yuhui; Wang, Guangfeng; Yu, Fei; Zhang, Xiaojun; Wang, Yunbing
err分享
err收藏
Boronate-based fluorescent carbon dot for rapid and selectively bacterial sensing by luminescence off/on system
err2018-09-01
err33
PREAI
errChoi, Cheong A.; Mazrad, Zihnil Adha Islamy; Lee, Gibaek; In, Insik; Lee, Kang Dae; Park, Sung Young
err分享
err收藏
err分享
err收藏
Combined Detection of Cancer Cells and a Tumor Biomarker using an Immunomagnetic Sensor for the Improvement of Prostate-Cancer Diagnosis
err2014-03-20
err37
errOAAI
errYang, Hung-Wei; Lin, Chih-Wen; Hua, Mu-Yi; Liao, Shih-Sheng; Chen, Ying-Tzu; Chen, Hsiao-Chien; Weng, Wen-Hui; Chuang, Cheng-Keng; Pang, See-Tong; Ma, Chen-Chi M.
err分享
err收藏
Vimentin-targeting AIEgen-peptide conjugates: Wash-free fluorescence detection of EMT-type cancer cells and tissues
err2020-10-01
err13
PREAI
errWei, Han; Yu, Yifang; Wang, Yueqin; Ying, Zhenzhen; Cheng, Weiyan; Tian, Xin; Kan, Quancheng
err分享
err收藏
学者 查看更多内容