This paper suggests and demonstrates a novel flow measurement technique: tunable AC thermal anemometry, that allows simple integration, robust measurement and extremely high accuracy. The principle and simple theoretical analysis of the technique are presented. To find the optimal condition at which the phase lag becomes most sensitive to the flow speed change, the phase lag was measured scanning the heating frequency from 1 to 100 Hz, while the flow speed of ethanol was increased stepwise from 0 to 40 mm/s. The sensitivity of the phase lag depended on the heating frequency and the flow speed. It was possible to measure the average flow speed of 0.7 mm/s with the resolution of 0. 1 mm/s at 4 Hz. (C) 2004 Elsevier Ltd. All rights reserved.
Keyword:
thermal anemometry
phase lag
alternating current
hot-wire
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
3.3
论文数:
6.8K
被引数:
9.0K
机构
暂无机构信息
引用论文
Thermal flow sensor for liquids and gases based on combinations of two principles基于两种原理组合的液体和气体热式流量传感器