arrow
返回

Urinary bladder segmentation in CT urography using deep-learning convolutional neural network and level sets

delete2016-03-23
delete210
delete
OA
AI
H
H. Kenny *
L
Lubomir M. Hadjiiski
R
Ravi K. Samala
Heang-Ping Chan 封面图
Heang-Ping Chan (Heang‐Ping Chan)
E
Elaine M. Caoili
R
Richard H. Cohan
DOI:10.1118/1.4944498delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Purpose: The authors are developing a computerized system for bladder segmentation in CT urography (CTU) as a critical component for computer-aided detection of bladder cancer. Methods: A deep-learning convolutional neural network (DL-CNN) was trained to distinguish between the inside and the outside of the bladder using 160 000 regions of interest (ROI) from CTU images. The trained DL-CNN was used to estimate the likelihood of an ROI being inside the bladder for ROIs centered at each voxel in a CTU case, resulting in a likelihood map. Thresholding and hole-filling were applied to the map to generate the initial contour for the bladder, which was then refined by 3D and 2D level sets. The segmentation performance was evaluated using 173 cases: 81 cases in the training set (42 lesions, 21 wall thickenings, and 18 normal bladders) and 92 cases in the test set (43 lesions, 36 wall thickenings, and 13 normal bladders). The computerized segmentation accuracy using the DL likelihood map was compared to that using a likelihood map generated by Haar features and a random forest classifier, and that using our previous conjoint level set analysis and segmentation system (CLASS) without using a likelihood map. All methods were evaluated relative to the 3D hand-segmented reference contours. Results: With DL-CNN-based likelihood map and level sets, the average volume intersection ratio, average percent volume error, average absolute volume error, average minimum distance, and the Jaccard index for the test set were 81.9% +/- 12.1%, 10.2% +/- 16.2%, 14.0% +/- 13.0%, 3.6 +/- 2.0 mm, and 76.2% +/- 11.8%, respectively. With the Haar-feature-based likelihood map and level sets, the corresponding values were 74.3% +/- 12.7%, 13.0% +/- 22.3%, 20.5% +/- 15.7%, 5.7 +/- 2.6 mm, and 66.7% +/- 12.6%, respectively. With our previous CLASS with local contour refinement (LCR) method, the corresponding values were 78.0% +/- 14.7%, 16.5% +/- 16.8%, 18.2% +/- 15.0%, 3.8 +/- 2.3 mm, and 73.9% +/- 13.5%, respectively. Conclusions: The authors demonstrated that the DL-CNN can overcome the strong boundary between two regions that have large difference in gray levels and provides a seamless mask to guide level set segmentation, which has been a problem for many gradient-based segmentation methods. Compared to our previous CLASS with LCR method, which required two user inputs to initialize the segmentation, DL-CNN with level sets achieved better segmentation performance while using a single user input. Compared to the Haar-feature-based likelihood map, the DL-CNN-based likelihood map could guide the level sets to achieve better segmentation. The results demonstrate the feasibility of our new approach of using DL-CNN in combination with level sets for segmentation of the bladder. (C) 2016 American Association of Physicists in Medicine.
Keyword:
computer-aided detection
deep-learning
segmentation
CT urography
bladder
level set
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

U
university of michigan system
学者数:
9.1W
论文数: 8.6W
被引数: 133
引用论文

引用论文

Detection of urinary bladder mass in CT urography with SPAN
err2015-06-22
err9
errOAAI
errCha, Kenny; Hadjiiski, Lubomir; Chan, Heang-Ping; Cohan, Richard H.; Caoili, Elaine M.; Zhou, Chuan
err分享
err收藏
Automated regional registration and characterization of corresponding microcalcification clusters on temporal pairs of mammograms for interval change analysis
err2008-11-07
err13
errOAAI
errFilev, Peter; Hadjiiski, Lubomir; Chan, Heang-Ping; Sahiner, Berkman; Ge, Jun; Helvie, Mark A.; Roubidoux, Marilyn; Zhou, Chuan
err分享
err收藏
High‐mobility oxide TFT for circuit integration of AMOLEDs
err2012-06-18
err0
PREAI
errEri Fukumoto; Toshiaki Arai; Narihiro Morosawa; Kazuhiko Tokunaga; Yasuhiro Terai; Takashige Fujimori; Tatsuya Sasaoka
err分享
err收藏
257 Are Stethoscopes and Infection Control Enemies?
err2020-10-01
err0
PREAI
errS. Kalra; J.B. Shewale; W.F. Peacock
err分享
err收藏
Hematuria: Portal venous phase multi-detector row CT of the bladder - A prospective study
errRADIOLOGY
IF15.2
err2007-12-01
err44
PREAI
errPark, Sung Bin; Kim, Jeong Kon; Lee, Hyun Joo; Choi, Hyuck Jae; Cho, Kyoung-Sik
err分享
err收藏
Multidetector computerized tomography urography as the primary imaging modality for detecting urinary tract neoplasms in patients with asymptomatic hematuria
err2008-03-01
err80
PREAI
errSudakoff, Gary S.; Dunn, Dell P.; Guralnick, Michael L.; Hellman, Robert S.; Eastwood, Daniel; See, William A.
err分享
err收藏
学者 查看更多内容