Velocity selective spin labeling using parallel transmission

delete2023-12-04
delete1
delete
OA
AI
C
Chia‐Yin Wu *
J
Jin Jin
C
Carl Dixon
D
Donald Maillet
M
Markus Barth
M
Martijn A. Cloos
DOI:10.1002/mrm.29955delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Purpose: Ultra-high field (UHF) provides improved SNR which greatly benefits SNR starved imaging techniques such as perfusion imaging. However, transmit field (B1+) inhomogeneities commonly observed at UHF hinders the excitation uniformity. Here we show how replacing standard excitation pulses with parallel transmit pulses can improve efficiency of velocity selective labeling. Methods: The standard tip-down and tip-up excitation pulses found in a velocity selective preparation module were replaced with tailored non-selective kT-points pulse solutions. Bloch simulations and experimental validation on a custom-built flow phantom and in vivo was performed to evaluate different pulse configurations in circularly polarized mode (CP-mode) and parallel transmit (pTx) mode. Results: Tailored pTx pulses significantly improved velocity selective labeling fidelity and signal uniformity. The transverse magnetization normalized RMS error was reduced from 0.489 to 0.047 when compared to standard rectangular pulses played in CP-mode. Simulations showed that manipulation of time symmetry in the tailored pTx pulses is vital in minimizing residual magnetization. In addition, in vivo experiments achieved a 44% lower RF power output and a shorter pulse duration when compared to using adiabatic pulses in CP-mode. Conclusion: Using tailored pTx pulses for excitation within a velocity selective labeling preparation mitigated transmit field artifacts and improved SNR and contrast fidelity. The improvement in labeling efficiency highlights the potential of using pTx to improve robustness and accessibility of flow-based sequences such as velocity selective spin labeling at ultra-high field.
Keyword:
flow encoding
parallel transmission (pTx)
ultra-high field
velocity selective labeling

期刊

Magnetic Resonance in Medicine 封面图
Magnetic Resonance in Medicine
IF:
3
论文数:
1.2W
被引数:
3.1W

机构

U
University of Queensland
学者数:
5.0W
论文数: 5.1W
被引数: 9.2W
引用论文

引用论文

Improving T2-Weighted Imaging at High Field Through the Use of kT-Points
err2013-06-20
err33
errOAAI
errEggenschwiler, Florent; O'Brien, Kieran R.; Gruetter, Rolf; Marques, Jose P.
err分享
err收藏
Multiple elimination using a pattern‐recognition technique
err1999-01-01
err0
PREAI
errAntoine Guitton; Guillaume Cambois
err分享
err收藏
Transmit SENSE
err2002-12-31
err766
errOAAI
errKatscher, U; Börnert, P; Leussler, C; van den Brink, JS
err分享
err收藏
err
IF0
err
err0
PREAI
err
err分享
err收藏
Phase-Contrast MRI: Physics, Techniques, and Clinical Applications
err2020-01-01
err115
PREAI
errWymer, David T.; Patel, Kunal P.; Burke, William F., III; Bhatia, Vinay K.
err分享
err收藏
Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy
err2005-12-12
err193
PREAI
errOrdidge, RJ; Wylezinska, M; Hugg, JW; Butterworth, E; Franconi, F
err分享
err收藏
学者 查看更多内容