arrow
返回

Zero-Interfacing ?HPLC to ICPMS

delete2022-11-08
delete1
PRE
AI
周
周旸 (Yang Zhou)
X
Xingrui Song
严
严晓文 (Xiaowen Yan)
杨
杨利民 (Limin Yang)
S
Shi Chen
王
王秋泉 (Qiuquan Wang) *
DOI:10.1021/acs.analchem.2c03951delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
The chromatography-mass spectrometry hyphenated technique is the most widely adopted tool for quantifying trace analytes in a complex biosample. One issue we frequently encountered, however, is that the separated analyte-containing chromatographic peaks broaden and even remix prior to mass spectrometric quantification due to the inevitable molecular diffusion within the dead-volume introduced by hyphenation. We developed a zero-interfacing approach for coupling microbore (mu) HPLC with inductively coupled plasma mass spectrometry (ICPMS). Zero-interfacing mu HPLC to ICPMS has been achieved by a columnnebulizer assembly (COL-NEB) of a self-designed glass framework with a tapered nozzle, in which a capillary chromatographic column can be harbored while an Ar gas flow is blown through the nozzle mouth. The COL-NEB can be positioned just before the base of the Ar-ICP serving as the central sampling channel of a conventional Ar-ICP torch for online nebulization and transportation of the analytes separated on mu HPLC into ICPMS, maintaining the molecular resolution obtained on mu HPLC and the limit of detection (LOD) of ICPMS. For example, the full width at half-maximum of a SLUGT peptide chromatographic peak was reduced to 1.71 +/- 0.07 s (n = 5) with a 0.72 fg LOD (3a) of 80Se. Moreover, at least 32 Se-containing peptides were determined in the trypsin lysate of the water-soluble fraction (>= 3000 MW) from Se-enriched yeast CRM SELM-1 within a 10 min run, the highest record to date. We believe such an approach paves the way to determining accurate information on a heteroatom and its binding biomolecules that play key roles during life processes.
Keyword:
HIGH-EFFICIENCY NEBULIZER
LIQUID-SAMPLE INTRODUCTION
PLASMA-MASS-SPECTROMETRY
ABSOLUTE QUANTIFICATION
FLOW-INJECTION
CHROMATOGRAPHY

期刊

Analytical Chemistry 封面图
Analytical Chemistry
IF:
6.7
论文数:
4.7W
被引数:
15.9W

机构

X
xiamen university
学者数:
5.9W
论文数: 3.8W
被引数: 67
引用论文

引用论文

Direct Infusion ICP-qMS of Lined-up Single-Cell Using an Oil-Free Passive Microfluidic System
err2020-03-17
err30
PREAI
errZhou, Yang; Chen, Zhangqian; Zeng, Juxing; Zhang, Jiaxuan; Yu, Danxia; Zhang, Bo; Yan, Xiaowen; Yang, Limin; Wang, Ququan
err分享
err收藏
Liquid-sample introduction in plasma spectrometry
err2003-03-01
err80
errOAAI
errMora, J; Maestre, S; Hernandis, V; Todolí, JL
err分享
err收藏
学者 查看更多内容