Abstract

Abstract

En 中文
A core-annular liquid-liquid microextractor (CALLME) has been applied to 10 vol% acetone-toluene and a mixture of alpha-methylbenzylamine/acetophenone-n-heptane extraction pairs as a robust screening tool for process development. In the CALLME, a stretchable helix wire was placed at the core position for the aqueous stream, and it was surrounded by the organic solvent to ensure a stable aqueous-organic contact interface. A theoretical governing equation for the operational pressure was formulated for device design. The CALLME has a large contact surface area and demonstrated > 90% extraction efficiency within 10 min. Further, we demonstrated its high operability in flow rate control, compatibility with different model systems, and scalability. Correlations relating the overall volumetric mass transfer coefficients to the residence time, flow rate ratio, and contact surface area are presented for both the CALLME and a bench-scale extraction continuous stirred-beaker reactor. The CALLME operates in a continuous flow mode, beneficial for rapid process characterization.
Keywords:
Liquid-liquid extraction
Core-annular flow
Microoperator
Overall volumetric mass transfer coefficient
Scale-up
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Chemical Engineering Journal cover
Chemical Engineering Journal
IF:
13.2
Papers:
7.6W
Citations:
48.5W

Organization

N
National Chung Hsing University
Scholars:
1.1W
Papers: 9.4K
Citations: 9
Cited Papers

Cited Papers

On the pinning of interfaces on micropillar edges
err2009-10-01
err60
PREAI
errBerthier, J.; Loe-Mie, F.; Tran, V. -M.; Schoumacker, S.; Mittler, F.; Marchand, G.; Sarrut, N.
errShare
errSave
Concentrations of interleukin-2 in the nasopharyngeal secretion of children with acute respiratory syncytial virus bronchiolitis
err2004-07-01
err0
errOAAI
errKatia M. Giugno; Denise C. Machado; Sérgio L. Amantéa; Sérgio S. Menna Barreto
errShare
errSave
Liquid membrane operations in a microfluidic device for selective separation of metal ions
err2004-07-08
err136
PREAI
errMaruyama, T; Matsushita, H; Uchida, J; Kubota, F; Kamiya, N; Goto, M
errShare
errSave
err
IF0
err
err0
PREAI
err
errShare
errSave
High-Throughput Liquid-Liquid Extractions with Nanoliter Volumes
err2020-01-28
err27
errOAAI
errWells, Shane S.; Kennedy, Robert T.
errShare
errSave
Scale-up concept of single-channel microreactors from process development to industrial production
err2011-03-01
err196
PREAI
errKockmann, Norbert; Gottsponer, Michael; Roberge, Dominique M.
errShare
errSave
Microfluidic Droplet-Based Liquid-Liquid Extraction and On-Chip IR Spectroscopy Detection of Cocaine in Human Saliva
err2013-07-18
err66
PREAI
errWaegli, Philip; Chang, Yu-Chi; Homsy, Alexandra; Hvozdara, Lubos; Herzig, Hans Peter; de Rooij, Nico F.
errShare
errSave
Co and Ni extraction and separation in segmented micro-flow using a coiled flow inverter
err2017-01-01
err82
errOAAI
errZhang, Lihua; Hessel, Volker; Peng, Jinhui; Wang, Qi; Zhang, Libo
errShare
errSave
researcher View more