Return
A direct method for multi-loop PI/PID controller design
DOI:10.1016/S0959-1524(03)00009-X.png)
Abstract
En 中文
Difficulties caused by the interactions are always encountered in the design of multi-loop control systems for MIMO processes. To overcome the difficulties, a multi-loop system is decomposed into a number of equivalent single loops for design. For each equivalent single loop, an effective open-loop process (EOP) is formulated without prior knowledge of controller dynamics in other loops, and, hence, controller can be designed directly and independently. Based on the derived EOPs, a model-based method aims at having reasonable gain margins (e.g. greater than or equal to 2) and phase margins (e.g approximate to60degrees) are presented to derive multi-loop PI/PID controllers. This proposed method is formulated in details for the EOPs of 2-loop systems. Extension to higher dimensional systems needs further simplification and is illustrated with formulation for 3-loop systems. Simulation results show that this presented method is effective for square MIMO processes, especially, for low dimensional ones. (C) 2003 Elsevier Ltd. All rights reserved.
Keywords:
multi-loop
dynamic interaction
PI/PID controller
effective open-loop process
low-dimensional system
AI Summary
Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.
Journal
IF:
3.9
Papers:
3.5K
Citations:
7.3K
Organization
No organization information available