arrow
Return

A Fast Normalized Cross-Correlation Calculation Method for Motion Estimation

delete2010-06-01
delete358
delete
OA
AI
罗建文 cover
罗建文 (Jianwen Luo) *
E
Elisa E. Konofagou
DOI:10.1109/TUFFC.2010.1554delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
High-precision motion estimation has become essential in ultrasound-based techniques such as time-domain Doppler and elastography. Normalized cross-correlation (NCC) has been shown as one of the best motion estimators. However, a significant drawback is its associated computational cost, especially when RF signals are used. In this paper, a method based on sum tables developed elsewhere is adapted for fast NCC calculation in ultrasound-based motion estimation, and is tested with respect to the speed enhancement of the specific application of ultrasound-based motion estimation. Both the numerator and denominator in the NCC definition are obtained through pre-calculated sum tables to eliminate redundancy of repeated NCC calculations. Unlike a previously reported method, a search region following the principle of motion estimation is applied in the construction of sum tables. Because an exhaustive search and high window overlap are typically used for highest quality imaging, the computational cost of the proposed method is significantly lower than that of the direct method using the NCC definition, without increasing bias and variance characteristics of the motion estimation or sacrificing the spatial resolution. Therefore, high quality, high spatial resolution, and high calculation speed can be all simultaneously obtained using the proposed methodology. The high efficiency of this method was verified using RF signals from a human abdominal aorta in vivo. For the parameters typically used, a real-time, very high frame rate of 310 frames/s was achieved for the motion estimation. The proposed method was also extended to 2-D NCC motion estimation and motion estimation with other algorithms. The technique could thus prove very useful and flexible for real-time motion estimation as well as in other fields such as optical flow and image registration.
Keywords:
DELAY ESTIMATION
BLOOD-FLOW
DISPLACEMENT ESTIMATORS
ULTRASONIC STRAIN
FUNDAMENTAL LIMIT
AXIAL RESOLUTION
TIME
ELASTOGRAPHY
PERFORMANCE
ALGORITHMS

Journal

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control cover
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
IF:
3.7
Papers:
6.7K
Citations:
1.4W

Organization

C
Columbia University
Scholars:
7.1W
Papers: 6.4W
Citations: 263
Cited Papers

Cited Papers

Synthesis of optically active (+)-D-3,4,5-tri O-phenylcarbamoyl Myo-inositol from phytic acid
err1995-10-01
err0
PREAI
errCorinne Blum; Susanne Karlsson; Gilbert Schlewer; Bernard Spiess; Nicola Rehnberg
errShare
errSave
Effect of Enflurane on Contractile Reactivity in Isolated Canine Mesenteric Arteries and Veins
err1990-05-01
err0
errOAAI
errYutaka Kobayashi; Kazu-ichi Yoshida; Masahiro Noguchi; Yoshifumi Wakasugi; Haruo Ito; Eiichiro Okabe
errShare
errSave
researcher View more