arrow
Return

A low-count reconstruction algorithm for Compton-based prompt gamma imaging

delete2018-04-19
delete3
PRE
AI
H
Hsuan‐Ming Huang *
C
Chih‐Chieh Liu
M
Ming-Wei Lee
DOI:10.1088/1361-6560/aab737delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
The Compton camera is an imaging device which has been proposed to detect prompt gammas (PGs) produced by proton-nuclear interactions within tissue during proton beam irradiation. Compton-based PG imaging has been developed to verify proton ranges because PG rays, particularly characteristic ones, have strong correlations with the distribution of the proton dose. However, accurate image reconstruction from characteristic PGs is challenging because the detector efficiency and resolution are generally low. Our previous study showed that point spread functions can be incorporated into the reconstruction process to improve image resolution. In this study, we proposed a low-count reconstruction algorithm to improve the image quality of a characteristic PG emission by pooling information from other characteristic PG emissions. PGs were simulated from a proton beam irradiated on a water phantom, and a two-stage Compton camera was used for PG detection. The results show that the image quality of the reconstructed characteristic PG emission is improved with our proposed method in contrast to the standard reconstruction method using events from only one characteristic PG emission. For the 4.44 MeV PG rays, both methods can be used to predict the positions of the peak and the distal falloff with a mean accuracy of 2 mm. Moreover, only the proposed method can improve the estimated positions of the peak and the distal falloff of 5.25 MeV PG rays, and a mean accuracy of 2 mm can be reached.
Keywords:
proton therapy
Compton camera
prompt gamma ray
low count
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Physics in Medicine and Biology cover
Physics in Medicine and Biology
IF:
3.4
Papers:
1.4W
Citations:
3.1W

Organization

N
National Taiwan University
Scholars:
4.7W
Papers: 4.2W
Citations: 3.6W
U
university of california davis
Scholars:
3.4W
Papers: 2.6W
Citations: 45
University of California System cover
University of California System
Scholars:
37.7W
Papers: 33.8W
Citations: 6.6K
researcher View more organizations
Cited Papers

Cited Papers

First clinical application of a prompt gamma based in vivo proton range verification system
err2016-02-01
err231
errOAAI
errRichter, Christian; Pausch, Guntram; Barczyk, Steffen; Priegnitz, Marlen; Keitz, Isabell; Thiele, Julia; Smeets, Julien; Stappen, Francois Vander; Bombelli, Luca; Fiorini, Carlo; Hotoiu, Lucian; Perali, Irene; Prieels, Damien; Enghardt, Wolfgang; Baumann, Michael
errShare
errSave
Prompt gamma measurements for locating the dose falloff region in the proton therapy
err2006-11-02
err352
PREAI
errMin, Chul-Hee; Kim, Chan Hyeong; Youn, Min-Young; Kim, Jong-Won
errShare
errSave
errShare
errSave
Noise evaluation of Compton camera imaging for proton therapy
err2015-02-06
err52
PREAI
errOrtega, P. G.; Torres-Espallardo, I.; Cerutti, F.; Ferrari, A.; Gillam, J. E.; Lacasta, C.; Llosa, G.; Oliver, J. F.; Sala, P. R.; Solevi, P.; Rafecas, M.
errShare
errSave
Compton Camera and Prompt Gamma Ray Timing: Two Methods for In Vivo Range Assessment in Proton Therapy
err2016-04-12
err49
errOAAI
errHueso-Gonzalez, Fernando; Fiedler, Fine; Golnik, Christian; Kormoll, Thomas; Pausch, Guntram; Petzoldt, Johannes; Roemer, Katja E.; Enghardt, Wolfgang
errShare
errSave
Use of a LYSO-based Compton camera for prompt gamma range verification in proton therapy
err2017-11-03
err21
PREAI
errJan, Meei-Ling; Hsiao, Ing-Tsung; Huang, Hsuan-Ming
errShare
errSave
errShare
errSave
Prompt gamma-ray emission from biological tissues during proton irradiation: a preliminary study
err2009-01-09
err98
PREAI
errPolf, J. C.; Peterson, S.; Ciangaru, G.; Gillin, M.; Beddar, S.
errShare
errSave
researcher View more