A Miniaturized FBG Accelerometer Based on a Thin Polyurethane Shell

delete2016-03-01
delete26
PRE
AI
J
Jun Wang
Y
Yujie Zeng *
C
Chongyu Lin
Z
Zhengliang Hu
G
Gang‐Ding Peng *
Y
Yongming Hu *
DOI:10.1109/JSEN.2015.2501983delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
A miniaturized fiber bragg grating accelerometer based on a thin polyurethane shell is designed and tested. The FBG accelerometer is based on spring-mass structure. The elastic body is a thin polyurethane cylindrical shell. By inserting the mass into the inner of the shell, the accelerometer axial size is reduced by half compared with traditional ones in which masses are exposed outside. The theoretical performance limit of the miniaturized accelerometer is discussed. Test results show the miniaturized accelerometer has similar sensing performance as the traditional one. Size of the miniaturized accelerometer is Phi 23 mm x 17 mm, sensitivity over the flat frequency response zone is 54 pm/g, and resonant frequency is 480 Hz. Furthermore, orthogonal crosstalk of the miniaturized accelerometer is -17.75 dB which is 3 dB lower than the traditional one. Thus, this miniaturized design can reduce both size and orthogonal crosstalk of accelerometers based on elastic shells. This miniaturized structure can also be used in other fiber optic accelerometers based on shells.
Keywords:
FBG
accelerometer
miniaturized design
thin polyurethane shell
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

IEEE Sensors Journal cover
IEEE Sensors Journal
IF:
4.5
Papers:
2.2W
Citations:
7.3W

Organization

N
national university of defense technology - china
Scholars:
1.8W
Papers: 1.4W
Citations: 9
Cited Papers

Cited Papers

Characterization of cyclophosphamide-induced suppressor cells
err1982-08-01
err0
PREAI
errKevin R. McIntosh; Mariangela Segre; Diego Segre
errShare
errSave
errShare
errSave
errShare
errSave
Design optimization of fiber Bragg grating accelerometer for maximum sensitivity
err2013-05-01
err81
PREAI
errBasumallick, Nandini; Biswas, Palas; Dasgupta, Kamal; Bandyopadhyay, Somnath
errShare
errSave
Endovascular Treatment is an Accurate Option for Aortoenteric Secondary Fistulae in TASC D Patients
err2014-03-01
err0
errOAAI
errE.M. San Norberto; J.A. Brizuela; J.H. Taylor; S. Carrera; M.A. Ibáñez; C. Vaquero
errShare
errSave
Oil and gas applications: Probing oil fields
err2008-03-01
err49
PREAI
errNakstad, Hilde; Kringlebotn, Jon Thomas
errShare
errSave
errShare
errSave
researcher View more