arrow
Return

A new efficient error control algorithm for wireless sensor networks in smart grid

delete2019-03-01
delete18
PRE
AI
M
Melike Yiğit *
P
Pınar Sarısaray Bölük
V
Vehbi Çağrı Güngör
DOI:10.1016/j.csi.2018.11.006delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Error detection and correction is an important issue in the design and maintenance of a smart grid communication network to provide reliable communication between sender and receiver. Various error-control coding techniques are employed to reduce bit error rates (BER) in wireless sensor networks (WSNs). The performance of these techniques is also compared and evaluated to find the most suitable technique for WSNs. This is the first study to compare the most efficient coding techniques in the smart grid environment, and it suggests a new error correction algorithm based on this comparison result. Therefore, this article first examines and compares two forward error control (FEC) coding techniques such as Bose-Chaudhuri-Hochquenghem code (BCH) and Reed Solomon code (RS) with various modulation methods including frequency shift keying (FSK), offset quadrature phase-shift keying (OQPSK), and differential phase shift keying (DPSK) in a 500 kV line-of-sight (LoS) substation smart grid environment. Second, as a result of this comparison, a new adaptive error control (AEC) algorithm is proposed. Adaptive error control adaptively changes error correction code (ECC) based on the channel behavior that is observed through the packet error rate (PER) in the recent previous transmissions. The link-quality-aware capacitated minimum hop spanning tree (LQ-CMST) algorithm and the multi-channel scheduling algorithm are used for data transmission over the log-normal channel. Therefore, the performance of compared coding techniques and AEC are also evaluated when multiple channels are used during transmission Further, AEC is compared with static RS and without-FEC methods based on performance metrics such as the throughput, BER, and delay in different smart grid environments, e.g., 500 kV Substation (LoS), underground network transformer vaults (UTV) (LoS), and main power control room (MPR) (LoS). Our simulation results indicate that the proposed AEC algorithm achieves better performances than all those techniques.
Keywords:
Error detection and correction
Rs code
Bch code
Smart grid
Multi-channel scheduling
AEC
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

C
Computer Standards and Interfaces
IF:
3.1
Papers:
2.3K
Citations:
2.0K

Organization

B
Bahcesehir University
Scholars:
1.3K
Papers: 1.6K
Citations: 26
A
Abdullah Gul University
Scholars:
522
Papers: 607
Citations: 2