arrow
Return

A relaxometry method that emphasizes practicality and availability

delete2022-07-25
delete3
PRE
AI
B
Bruno Madore *
M
Michael Jerosch‐Herold
J
Jr‐yuan George Chiou
C
Cheng‐Chieh Cheng
J
Jeffrey P. Guenette
G
Georgeta Mihai
DOI:10.1002/mrm.29394delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Purpose Although many methods have been proposed to quantitatively map the main MRI parameters (e.g., T-1, T-2, C x M-0), these methods often involve special sequences not readily available on clinical scanners and/or may require long scan times. In contrast, the proposed method can readily run on most scanners, offer flexible tradeoffs between scan time and image quality, and map MRI parameters jointly to ensure spatial alignment. Methods The approach is based on the multi-shot spin-echo (SE) EPI sequence. The corresponding signal equation was derived and strategies for solving it were developed. As usual with multi-shot EPI, scan time can readily be traded-off against image quality by adjusting the echo train length. Validation was performed against reference relaxometry methods, in gel phantoms with varying concentrations of gadobutrol and gadoterate meglumine contrast agents. In vivo examples are further presented, from 3 neuroradiology patients. Results Bland-Altman analysis was performed: for T-2, as compared to 2D SE, bias was 0.29 ms and the 95% limits of agreement ranged from -1.15 to +1.73 ms. For T-1, compared to inversion-recovery SE (and MOLLI), bias was -20.2 ms (and -14.5 ms) and the limits of agreement ranged from -62.4 to +22.0 ms (and -53.8 to +24.9 ms). The mean relative T-1 error between the proposed method and each of the 2 reference methods was similar to that of the reference methods among themselves. Conclusion In the constellation of existing relaxometry methods, the proposed method is meant to stand out in terms of its practicality and availability.
Keywords:
parameter mapping
relaxometry
signal equation

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

H
Harvard University
Scholars:
26.5W
Papers: 22.0W
Citations: 28.7W
H
Harvard Medical School
Scholars:
6.5W
Papers: 4.8W
Citations: 91
Cited Papers

Cited Papers

Dynamic movements of Ro52 cytoplasmic bodies along microtubules
err2009-12-16
err0
errOAAI
errMakoto Tanaka; Kunikazu Tanji; Motoko Niida; Tetsu Kamitani
errShare
errSave
Gleaning Multicomponent T1 and T2 Information From Steady-State Imaging Data
err2008-11-24
err398
PREAI
errDeoni, Sean C. L.; Rutt, Brian K.; Arun, Tarunya; Pierpaoli, Carlo; Jones, Derek K.
errShare
errSave
Reproducibility and Repeatability of MR Fingerprinting Relaxometry in the Human Brain
errRADIOLOGY
IF15.2
err2019-08-01
err82
PREAI
errKoerzdoerfer, Gregor; Kirsch, Rainer; Liu, Kecheng; Pfeuffer, Josef; Hensel, Bernhard; Jiang, Yun; Ma, Dan; Gratz, Marcel; Baer, Peter; Bogner, Wolfgang; Springer, Elisabeth; Cardoso, Pedro Lima; Umutlu, Lale; Trattnig, Siegfried; Griswold, Mark; Gulani, Vikas; Nittka, Mathias
errShare
errSave
Rapid Estimation of Cartilage T2 Based on Double Echo at Steady State (DESS) With 3 Tesla
err2009-06-12
err93
errOAAI
errWelsch, Goetz H.; Scheffler, Klaus; Mamisch, Tallal C.; Hughes, Timothy; Millington, Steven; Deimling, Michael; Trattnig, Siegfried
errShare
errSave
Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths
err2005-11-01
err1.5K
PREAI
errRohrer, M; Bauer, H; Mintorovitch, J; Requardt, M; Weinmann, HJ
errShare
errSave
Alterations in complement-induced shape change and stimulus-specific superoxide anion generation by neonatal calf neutrophils
err1989-12-01
err0
PREAI
errWendy Holden; David O. Slauson; Roland D. Zwahlen; M. Mitsu Suyemoto; Monique Dor�; Nancy R. Neilsen
errShare
errSave
Total hip replacement in developmental dysplasia using an oval-shaped cementless press-fit cup
err2012-03-01
err0
errOAAI
errBoris M. Holzapfel; Felix Greimel; Peter M. Prodinger; Hakan Pilge; Ulrich Nöth; Hans Gollwitzer; Maximilian Rudert
errShare
errSave
researcher View more