arrow
Return

A scheme for multisource interior tomography

delete2009-07-06
delete56
delete
OA
AI
王
王高峰 (Ge Wang) *
H
Hengyong Yu
Y
Yangbo Ye
DOI:10.1118/1.3157103delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Currently, x-ray computed tomography (CT) requires source scanning so that projections can be collected from various orientations for image reconstruction. Limited by the scanning time, the temporal resolution of CT is often inadequate when rapid dynamics is involved in an object to be reconstructed. To meet this challenge, here the authors propose a scheme of multisource interior tomography for ultrafast imaging that reconstructs a relatively small region of interest (ROI). Specifically, such a ROI is irradiated in parallel with narrow x-ray beams defined by many source-detector pairs for data acquisition. This ROI can be then reconstructed using the interior tomography approach. To demonstrate the merits of this approach, the authors report interior reconstruction from in vivo lung CT data at a much reduced radiation dose, which is roughly proportional to the ROI size. The results suggest a scheme for ultrafast tomography (such as with a limited number of sources and in a scanning mode) to shorten data acquisition time and to suppress motion blurring.
Keywords:
computerised tomography
image reconstruction
lung
medical image processing
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Medical Physics cover
Medical Physics
IF:
3.2
Papers:
3.7W
Citations:
3.2W

Organization

U
University of Iowa
Scholars:
2.8W
Papers: 2.3W
Citations: 600
Cited Papers

Cited Papers

Managing Fecal Incontinence: SELF-CARE PRACTICES OF OLDER ADULTS
err2005-07-01
err0
PREAI
errDonna Zimmaro Bliss; Lucy Rose Fischer; Kay Savik
errShare
errSave
An iterative algorithm for X-ray CT fluoroscopy
err1998-01-01
err37
PREAI
errWang, G; Schweiger, G; Vannier, MW
errShare
errSave
errShare
errSave
Clinical and in vitro cross-reactivity of cereal grains in children with IgE-mediated wheat allergy
err2020-11-01
err0
PREAI
errWitchaya Srisuwatchari; Surapon Piboonpocanun; Unchalee Wangthan; Orathai Jirapongsananuruk; Nualanong Visitsunthorn; Punchama Pacharn
errShare
errSave
Tiny a priori knowledge solves the interior problem in computed tomography
err2008-04-09
err214
errOAAI
errKudo, Hiroyuki; Courdurier, Matias; Noo, Frederic; Defrise, Michel
errShare
errSave
HIGH-SPEED 3-DIMENSIONAL X-RAY COMPUTED-TOMOGRAPHY - THE DYNAMIC SPATIAL RECONSTRUCTOR
err1983-01-01
err105
PREAI
errROBB, RA; HOFFMAN, EA; SINAK, LJ; HARRIS, LD; RITMAN, EL
errShare
errSave
Half-scan cone-beam CT fluoroscopy with multiple x-ray sources
err2001-07-06
err73
PREAI
errLiu, Y; Liu, H; Wang, Y; Wang, G
errShare
errSave
Empirical evidence for the relationship between cognitive workload and attentional reserve
err2017-11-01
err0
PREAI
errKyle J. Jaquess; Rodolphe J. Gentili; Li-Chuan Lo; Hyuk Oh; Jing Zhang; Jeremy C. Rietschel; Matthew W. Miller; Ying Ying Tan; Bradley D. Hatfield
errShare
errSave
errShare
errSave
researcher View more