arrow
Return

Absolute Encoder-Based Dual Axis Tilt Sensor

delete2019-04-01
delete9
PRE
AI
T
Tuhin Subhra Sarkar
S
Subir Das
B
Badal Chakraborty *
H
Himadri Sekhar Dutta
DOI:10.1109/JSEN.2018.2887026delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
In this paper, an optical type dual axis tilt sensor is demonstrated for the measurement of surface inclination in the range of +/- 90 degrees. The proposed sensor measured the surface tilt by tracking a pendulum motion in two different axes. Unlike the traditional tilt sensor, the proposed concept used an absolute encoder for sensing the pendulum motion. This newly designed encoding track (named as index and code track) is attached separately with two pendulum blocks. As the encoder tracks are used a gray color coded pattern instead of binary code, hence the pendulum position is encoded as the variant intensity of gray colors. Thus, during the inclination of the sensor, a pair of optical trans-receiver reads the pendulum position by capturing the track information's as well as transformed it into the variant intensity of lights. Furthermore, a simple signal processing circuit has been used for calibrating the light intensity as measured surface inclination. The static behavior of the proposed sensor has been observed in laboratory conditions and found satisfactory performance in the above-mentioned measured range.
Keywords:
Dual axis tilt sensor
grayscale image
absolute encoder
pendulum structure
signal processing circuit (SPC)
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

IEEE Sensors Journal cover
IEEE Sensors Journal
IF:
4.5
Papers:
2.2W
Citations:
7.3W

Organization

K
kalyani government engineering college
Scholars:
148
Papers: 163
Citations: 0
B
bidhan chandra agricultural university
Scholars:
790
Papers: 442
Citations: 0
Cited Papers

Cited Papers

BREAST METASTASES FROM PRIMARY LEIOMYOSARCOMA
err2008-01-21
err0
PREAI
errN. R. Tulasi; S. Kurian; G. Mathew; F. R. Viswanathan; R. K. Roul
errShare
errSave
Estrogen and progesterone receptor assays on breast carcinoma from mastectomy specimens
err1983-12-01
err0
PREAI
errJohn S. Meyer; Kenneth Schechtman; Roland Valdes
errShare
errSave
A simple, low-cost, high-sensitivity fiber-optic tilt sensor
err2012-10-01
err42
PREAI
errBajic, Jovan S.; Stupar, Dragan Z.; Manojlovic, Lazo M.; Slankamenac, Milos P.; Zivanov, Milos B.
errShare
errSave
A rare case of breast carcinoma co-existing with axillary mantle cell lymphoma
err2003-12-09
err0
errOAAI
errSubhajit Dutta Roy; Joanna A Stafford; John Scally; S N Selvachandran
errShare
errSave
Fuel level measurement system based on absolute shaft encoder
err2017-06-01
err4
PREAI
errSarkar, Tuhin Subhra; Das, Subir; Chakraborty, Badal; Dutta, Himadri Sekhar
errShare
errSave
Longitudinal Competency-Based Point-of-Care Ultrasound Curriculum in Anesthesiology: Description and Initial Experience With PGY1 and PGY2 Trainees
err2020-03-01
err0
PREAI
errMegan M. Rashid; Laura A. Lahaye; Christa L. Riley; Spencer Liebman; William P. Murphy; Pranav R. Shah
errShare
errSave
Tilt measurement sensor
err2000-04-01
err46
PREAI
errBaltag, O; Costandache, D; Salceanu, A
errShare
errSave
researcher View more