arrow
Return

Accelerated radial diffusion spectrum imaging using a multi-echo stimulated echo diffusion sequence

delete2017-03-31
delete10
delete
OA
AI
S
Steven H. Baete *
F
Fernando E. Boada
DOI:10.1002/mrm.26682delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
PurposeDiffusion spectrum imaging (DSI) provides us non-invasively and robustly with anatomical details of brain microstructure. To achieve sufficient angular resolution, DSI requires a large number of q-space samples, leading to long acquisition times. This need is mitigated here by combining the beneficial properties of Radial q-space sampling for DSI with a Multi-Echo Stimulated Echo Sequence (MESTIM). MethodsFull 2D k-spaces for each of several q-space samples, along the same radially outward line in q-space, are acquired in one readout train with one spin and three stimulated echoes. RF flip angles are carefully chosen to distribute spin magnetization over the echoes and the DSI reconstruction is adapted to account for differences in diffusion time among echoes. ResultsIndividual datasets and bootstrapped reproducibility analysis demonstrate image quality and SNR of the more-than-twofold-accelerated RDSI MESTIM sequence. Orientation distribution functions (ODF) and tractography results benefit from the longer diffusion times of the latter echoes in the echo train. ConclusionA MESTIM sequence can be used to shorten RDSI acquisition times significantly without loss of image or ODF quality. Further acceleration is possible by combination with simultaneous multi-slice techniques. Magn Reson Med 79:306-316, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
Keywords:
diffusion spectrum imaging
RDSI
radial q-space acquisition
stimulated echo
multi-echo
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Magnetic Resonance in Medicine cover
Magnetic Resonance in Medicine
IF:
3
Papers:
1.2W
Citations:
3.1W

Organization

N
New York University
Scholars:
4.4W
Papers: 3.9W
Citations: 5.8W
Cited Papers

Cited Papers

AxCaliber: A method for measuring axon diameter distribution from diffusion MRI
err2008-05-27
err729
errOAAI
errAssaf, Yaniv; Blumenfeld-Katzir, Tamar; Yovel, Yossi; Basser, Peter J.
errShare
errSave
Multiband Phase-Constrained Parallel MRI
err2013-02-25
err42
errOAAI
errBlaimer, Martin; Choli, Morwan; Jakob, Peter M.; Griswold, Mark A.; Breuer, Felix A.
errShare
errSave
Impact of diabetes mellitus on the detection of prostate cancer via contemporary multi (≥12)‐core prostate biopsy
err2011-04-25
err0
errOAAI
errSung Kyu Hong; Jong Jin Oh; Seok‐Soo Byun; Sung Il Hwang; Hak Jong Lee; Gheeyoung Choe; Sang Eun Lee
errShare
errSave
Diffusion in Realistic Biophysical Systems Can Lead to Aliasing Effects in Diffusion Spectrum Imaging
err2015-12-30
err6
errOAAI
errLacerda, Luis M.; Sperl, Jonathan I.; Menzel, Marion I.; Sprenger, Tim; Barker, Gareth J.; Dell'Acqua, Flavio
errShare
errSave
Accelerated Diffusion Spectrum Imaging in the Human Brain Using Compressed Sensing
err2011-08-16
err112
errOAAI
errMenzel, Marion I.; Tan, Ek T.; Khare, Kedar; Sperl, Jonathan I.; King, Kevin F.; Tao, Xiaodong; Hardy, Christopher J.; Marinelli, Luca
errShare
errSave
Single‐stage high‐power factor half‐bridge flyback converter with synchronous rectifier
err2014-01-01
err0
errOAAI
errKyu‐Tae Kim; Jung‐Min Kwon; Han‐Mo Lee; Bong‐Hwan Kwon
errShare
errSave
researcher View more