arrow
Return

Accelerometer use in a physical activity intervention trial

delete2010-11-01
delete47
delete
OA
AI
M
Melissa A. Napolitano *
K
Kelley E. Borradaile
B
Beth A. Lewis
J
Jessica A. Whiteley
J
Jaime L. Longval
A
Alfred F. Parisi
A
Anna E. Albrecht
C
Christopher Sciamanna
J
John M. Jakicic
G
George D. Papandonatos
B
Bess H. Marcus
DOI:10.1016/j.cct.2010.08.004delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
This paper describes the application of best practice recommendations for using accelerometers in a physical activity (PA) intervention trial, and the concordance of different methods for measuring PA. A subsample (n = 63; 26%) of the 239 healthy, sedentary adults participating in a PA trial (mean age = 47.5; 82% women) wore the ActiGraph monitor at all 3 assessment time points. ActiGraph data were compared with self-report (i.e.. PA weekly recall and monthly log) and fitness variables. Correlations between the PA recall and ActiGraph for moderate intensity activity ranged from 0.16-0.48 and from 0.28-0.42 for vigorous intensity activity. ActiGraph and fitness [estimated VO2(ml/kg/min)] had correlations of 0.15-0.45. The ActiGraph and weekly self-report were significantly correlated at all time points (correlations ranged from 0.23 to 0.44). In terms of detecting intervention effects, intervention groups recorded more minutes of at least moderate-intensity PA on the ActiGraph than the control group at 6 months (min = 46.47, 95% Cl = -14.36-78.58), but not at 12 months. Limitations of the study include a small sample size and only 3 days of ActiGraph monitoring. To obtain optimal results with accelerometers in clinical trials, the authors recommend following best practice recommendations: detailed protocols for monitor use, calibration of monitors and validation of data quality, and use of validated equations for analysis. The ActiGraph has modest concordance with other assessment tools and is sensitive to change over time. However, until more information validating the use of accelerometry in clinical trials becomes available. properly administered self-report measures of PA should remain part of the assessment battery. (C) 2010 Elsevier Inc. All rights reserved.
Keywords:
Exercise
Objective monitoring
Best practice recommendations
ActiGraph
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Contemporary Clinical Trials cover
Contemporary Clinical Trials
IF:
1.9
Papers:
215
Citations:
5.7K

Organization

U
university of massachusetts system
Scholars:
3.8W
Papers: 3.5W
Citations: 42
U
University of Massachusetts Boston
Scholars:
2.4K
Papers: 1.9K
Citations: 4.2K
U
University of Minnesota Twin Cities
Scholars:
3.7W
Papers: 3.1W
Citations: 58
M
Miriam Hospital
Scholars:
765
Papers: 665
Citations: 753
T
Temple University
Scholars:
1.1W
Papers: 8.8K
Citations: 1.9W
P
pennsylvania commonwealth system of higher education (pcshe)
Scholars:
12.9W
Papers: 11.7W
Citations: 177
L
lifespan health rhode island
Scholars:
4.6K
Papers: 3.6K
Citations: 8
researcher View more organizations