1
Return

Accuracy of self-refraction using a portable device based on badal optics, iREF, in children in southern China: A cross-sectional study

delete2026-04-01
delete0
PRE
AI
W
Wang, Hongxi
W
Wu, Linrong
T
Tan, Xin
C
Chin, Man Pan
Q
Qiu, Kunliang
D
Du, Yali
Y
Yin, Shengjie
C
Chen, Binyao
J
Jiang, Jiao
C
Chen, Hailiu
Z
Zhang, Mingzhi *
DOI:10.1016/j.apjo.2026.100294delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Objective: To compare the refractive and visual accuracy between a portable device based on Badal optical system (iREF), noncycloplegic autorefraction, and cycloplegic subjective refraction. Methods: This cross-sectional study enrolled school-children aged 8-18 years in southern China. The operation procedure of self-refraction (SR) using iREF was taught by one researcher, and then the participants used iREF to test the spherical equivalent refraction (SE_SR) by themselves. Then, non-cycloplegic autorefraction (NCAR) was conducted and spherical equivalent (SE_NCAR) was calculated by another researcher. The third researcher, blind to the procedure and results above, performed subjective cycloplegic refraction (CR) and calculated SE_CR. Results: We enrolled 209 participants, with a mean age of 12.13 +/- 2.14 years old (males accounting 50.72 %) and a mean SE of -2.91 +/- 1.94 D. Bland-Altman plots showed 10 (4.8 %) of the right eye fell outside the 95 % consistency limit of SE_CR and SE_SR. The SE of the right eye by NCAR and SR was -3.03 +/- 1.93D and -2.94 +/- 1.89D, respectively. The error of SR (-0.03 +/- 0.36D) was significantly lower than that of NACR (-0.12 +/- 0.31D) (P < 0.001). The absolute error of SR was less than 0.50D in 185 cases (88.5 %), which was not significantly different from that of NCAR (190 cases, 90.9 %) (P = 0.487). High myopia (SE < -6.00 D) and high astigmatism (over 2.00 D) had more obvious errors than other groups. Conclusion: There is high consistency of the spherical equivalent measured by iREF self-refraction and cycloplegic refraction, while the accuracy diminishes in patients with high refractive errors.
Keywords:
Self-refraction
Portability
Spherical equivalent
Visual acuity
Myopia
Cycloplegic refraction
Noncycloplegic autorefraction

Journal

Asia-Pacific Journal of Ophthalmology cover
Asia-Pacific Journal of Ophthalmology
IF:
4.5
Papers:
2.0K
Citations:
2.3K

Organization

H
hong kong polytechnic university
Scholars:
3.0W
Papers: 4.0W
Citations: 921
S
shantou university
Scholars:
2.2K
Papers: 725
Citations: 0
Cited Papers

Cited Papers

Citing Papers

Citing Papers