Active Learning Under Expert-Budget Constraints: A Human-in-the-Loop Pipeline for Diabetic Retinopathy Lesion Detection

delete2026-07-02
delete0
delete
OA
AI
H
Hyeok Kim
S
Seok-Min Chang
B
Bo-Young Lim
S
Soo Young Lee
H
Ho-Gil Jung *
DOI:10.3390/bioengineering13070762delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Early diagnosis of Diabetic Retinopathy (DR) is critical for preventing irreversible vision loss, but precise lesion annotation by ophthalmologists is the dominant cost in building any clinical-grade DR detection model. The structural problem in real hospital settings is not labeling cost per se, but expert availability: ophthalmologists’ time is bounded by clinical duties, so the active-learning (AL) cycle can iterate only a handful of times in practice. We frame this constraint explicitly and ask which AL designs work best under a tight expert budget. We propose Virtuous Cycle, a Human-in-the-Loop (HITL) pipeline that integrates (i) a YOLOv8x-based object detector for microaneurysms, hemorrhages, and exudates, (ii) four AL sampling strategies (Average Confidence, Random, Hybrid-Diversity, Monte Carlo Dropout), and (iii) an in-hospital annotation platform (Diavision Studio) in which clinicians refine AI pre-labels rather than draw from scratch. We evaluate Virtuous Cycle on a real-world fundus dataset from the National Medical Center (NMC) across eight AL rounds, expanding the labeled pool from 81 images (R0) to 481 images (R8) within the actual expert-time budget of two ophthalmologists. Across three independent random seeds, random sampling dominates at cold start (mean mAP@50 0.14→0.25 over R0–R1), whereas Hybrid-Diversity converges to the highest mAP@50, Precision, and Recall by R7 (431 images; mAP@50 0.40, Precision 0.55, Recall 0.41), with MC Dropout close behind; by R8, the labeled pool is exhausted and all strategies converge to the same final model. A clinician crossover analysis of 36 paired clinical images, controlling for per-clinician speed bias and per-image difficulty bias, shows no statistically significant difference in overall per-image labeling time between AI-assisted and manual annotation ( p=0.52), but a statistically significant increase in confirmed lesion detections under AI assistance ( p=0.0058), driven predominantly (84– 100% of the net increase) by microaneurysms, the lesion type most prone to being missed unaided. The results indicate that, under expert-budget constraints, AL strategy choice should be staged: random sampling for cold start, uncertainty-and-diversity sampling once the model has matured, and that AI assistance trades a modest, lesion-burden-dependent time cost for a measurable gain in the sensitivity of microaneurysm detection.
Keywords:
diabetic retinopathy
active learning
human-in-the-loop
medical image annotation
YOLOv8
object detection
uncertainty quantification
Monte Carlo dropout

Journal

B
Bioengineering
IF:
3.7
Papers:
5.9K
Citations:
1.3W

Organization

N
National Medical Center
Scholars:
68
Papers: 40
Citations: 278
S
seoul national university of science and technology
Scholars:
458
Papers: 222
Citations: 0
Cited Papers

Cited Papers

Citing Papers

Citing Papers