Abstract
En 中文
<jats:sec>
<jats:title>Background:</jats:title>
<jats:p>CT angiography (CTA) is a key investigation in cerebrovascular disease. However, CTA is not always available and it also requires intravenous injection of iodinated contrast agents. It is increasingly possible to derive additional information from standard imaging sequences using artificial intelligence techniques. We investigated whether CTA maps could be derived from non-contrast CT (NCCT).</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Methods:</jats:title>
<jats:p>We conducted a retrospective, multicenter study across five Chinese hospitals, enrolling 3709 patients who underwent head NCCT paired with CTA. The dataset encompassed three cerebrovascular conditions: intracranial aneurysms (IA), intracranial atherosclerotic stenosis (IAS), and normal intracranial arteries. We developed the Cerebrovascular CTA Generative Artificial Intelligence Model (CTA-GAI) to synthesize CTA images directly from NCCT head scans. Synthetic outputs were evaluated against five typical models using quantitative metrics and visual assessment by clinicians. We also assessed the potential clinical utility of synthetic CTA for preliminary screening and triage by evaluating its ability to distinguish diseased from normal intracranial arteries and to classify common cerebrovascular subtypes.</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Results:</jats:title>
<jats:p>CTA-GAI demonstrated consistent and robust performance across both the validation and test sets. In internal validation, synthetic CTA images achieved a mean absolute error (MAE) of 0.0416, mean squared error (MSE) of 0.0178, peak signal-to-noise ratio (PSNR) of 25.59 dB, and structural similarity index measure (SSIM) of 85.41%. Clinicians assigned an average visual quality score of 4.45 out of 5. These metrics reflect close approximation to real CTA images. Performance remained consistent across four external validation sets. In a test set of 110 patients, clinicians achieved an overall accuracy, precision, sensitivity, specificity, and F1 score of 92.7%, 97.7%, 86.0%, 98.3%, and 91.5%, in distinguishing diseased intracranial arteries. Differentiation between IA and IAS within diseased arteries reached 90.7% accuracy.</jats:p>
</jats:sec>
<jats:sec>
<jats:title>Conclusion:</jats:title>
<jats:p>CTA-GAI can synthesize CTA-like images from NCCT that show promising utility for preliminary assessment in clinical practice. These results support its potential role as a rapid, low-cost, and non-invasive tool for large-scale screening or triage of cerebrovascular diseases.</jats:p>