arrow
Return

Alignment errors calibration for a channeled spectropolarimeter

delete2016-12-06
delete28
delete
OA
AI
杨斌 cover
杨斌 (Bin Yang)
X
Xueping Ju
C
Changxiang Yan
J
Junqiang Zhang *
DOI:10.1364/OE.24.028923delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
This paper presents a method to calibrate alignment errors for a channeled spectropolarimeter. A calibration model, including an alignment errors determination model and an alignment errors compensation model, is derived firstly. To determine the exact alignment errors of the high-order retarders and polarizer included in the spectropolarimeter, an auxiliary high-order retarder and a reference beam are used. The auxiliary high-order retarder does not affect the normal use of the spectropolarimeter and the polarization state of the reference beam needs not to be controlled accurately. Based on the determination results, the alignment errors are compensated by using a correction algorithm without any precise mechanical adjustments. Simulation results show that the alignment errors can be determined accurately and the errors of the reconstructed Stokes parameters due to the alignment errors are reduced effectively by the presented method. Finally, experimental results are summarized and analyzed to demonstrate the effectiveness of the calibration method. (C) 2016 Optical Society of America
Keywords:
HYPERSPECTRAL IMAGING POLARIMETER
MODULATION
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Optics Express cover
Optics Express
IF:
3.3
Papers:
6.1W
Citations:
14.3W

Organization

C
chinese academy of sciences
Scholars:
56.7W
Papers: 45.0W
Citations: 704
Cited Papers

Cited Papers

Time-resolved switching analysis of a ferroelectric liquid crystal by snapshot Mueller matrix polarimetry
err2010-03-29
err31
errOAAI
errDubreuil, Matthieu; Rivet, Sylvain; Le Jeune, Bernard; Dupont, Laurent
errShare
errSave
errShare
errSave
err
IF0
err
err0
PREAI
err
errShare
errSave
Nucleation Kinetics, Growth and Characterization Studies of a Diamagnetic Crystal‐Zinc Sulphate Heptahydrate (ZSHH)
err2009-01-16
err0
errOAAI
errR. Kanagadurai; R. Durairajan; R. Sankar; G. Sivanesan; S. P. Elangovan; R. Jayavel
errShare
errSave
Free-breathing real-time cardiac cine MR for evaluation of left-ventricular function: Comparison to standard multi-breath-hold cardiac cine MR in 50 patients
err2016-01-01
err0
errOAAI
errMasashi Nakamura; Tomoyuki Kido; Yoshiaki Komori; Michaela Schmidt; Christoph Forman; Kouki Watanabe; Teruhito Mochizuki
errShare
errSave
researcher View more