arrow
Return

An accurate and robust multicomponent quantitative analysis method: Molar mass coefficient method

delete2025-02-01
delete0
PRE
AI
X
Xi Chen
S
Siqi Ji
P
Pengyue Li
张立伟 (Liwei Zhang)
Y
Yihuan Wu
V
Verpoorte, Rob
Y
Yuntao Dai *
DOI:10.1016/j.chroma.2024.465644delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Multicomponent quantitative analysis (MCQA) is necessary for comprehensively characterizing the quality of complex samples, including medicines, foods. However, the limited supply of reference substances and the high costs associated with testing hinder the application of the MCQA using the external standard (ES) method. Here we propose a Molar Mass Coefficient (MMC) method for the quantification of multiple compounds with identical chromophore utilizing a single reference compound (SRC) by a UV detector. This method involves establishment of a linear equation of SRC (yr = axr+ b) with a standard compound r, followed by the derivation of quantitative equations for other components i using the deduced formula (yi = (Mr /Mi)axi + b). The MMC method introduces only two known physical parameters, specifically the molar mass of compounds r and i, which ensures both the accuracy and practicality of this method. The feasibility of the MMC method was demonstrated with a set of simulated samples containing 17 flavonoids standard compounds, and further validated with samples of Scutellariae Radix and Ginkgo dry extract. The newly established method could accurately quantify flavonoids, yielding results and robustness consistent with the traditional ES method. Notably, for the contents of baicalin and kaempferol, when compared to the results obtained by ES method, the relative standard deviations (RSD%) for the commonly used method were 5.72 % and 4.96 %, respectively, while these values fall down to 0.73 % and 1.02 % when employing the MMC method. The MMC method exhibited significant advantages over existing methods, including high accuracy, robustness and low cost, implying its broad application in different fields.
Keywords:
Molar mass coefficient method
Multicomponent quantitative analysis
Quantitative equation
Chromophore
Flavonoid

Journal

Journal of Chromatography A cover
Journal of Chromatography A
IF:
4
Papers:
3.2W
Citations:
5.0W

Organization

C
China Academy of Chinese Medical Sciences
Scholars:
8.8K
Papers: 4.5K
Citations: 1.1K
S
Shanxi University
Scholars:
1.3W
Papers: 8.4K
Citations: 1.2W
I
institute of chinese materia medica, cacms
Scholars:
811
Papers: 599
Citations: 0
researcher View more organizations