arrow
Return

An active learning representative subset selection method using net analyte signal

delete2018-05-01
delete5
PRE
AI
Z
Zhonghai He *
马
马振鹤 (Zhenhe Ma)
J
Jingmin Luan
才
才溪 (Xi Cai)
DOI:10.1016/j.saa.2018.02.038delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
To guarantee accurate predictions, representative samples are needed when building a calibration model for spectroscopic measurements. However, in general, it is not known whether a sample is representative prior to measuring its concentration, which is both time-consuming and expensive. In this paper, a method to determine whether a sample should be selected into a calibration set is presented. The selection is based on the difference of Euclidean norm of net analyte signal (NAS) vector between the candidate and existing samples. First, the concentrations and spectra of a group of samples are used to compute the projection matrix, NAS vector, and scalar values. Next, the NAS vectors of candidate samples are computed by multiplying projection matrix with spectra of samples. Scalar value of NAS is obtained by norm computation. The distance between the candidate set and the selected set is computed, and samples with the largest distance are added to selected set sequentially. Last, the concentration of the analyte is measured such that the sample can be used as a calibration sample. Using a validation test, it is shown that the presented method is more efficient than random selection. As a result, the amount of time and money spent on reference measurements is greatly reduced. (C) 2018 Elsevier B.V. All rights reserved.
Keywords:
Sample selection method
Net analyte signal
Representative subset
Active learning
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY cover
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY
IF:
4.6
Papers:
2.4W
Citations:
5.5W

Organization

N
northeastern university - china
Scholars:
3.2W
Papers: 2.7W
Citations: 37
Cited Papers

Cited Papers

errShare
errSave
Net analyte signal calculation in multivariate calibration
err1997-04-15
err380
PREAI
errLorber, A; Faber, K; Kowalski, BR
errShare
errSave
Comparative Analysis of M-ary Modulation Techniques for Wireless Ad-hoc Networks
err2007-02-01
err0
PREAI
errShakya Mukesh; Muddassir Iqbal; Zhang Jianhua; Zhang Ping; Inam-Ur-Rehman
errShare
errSave
Multivariate calibration
err2007-07-01
err67
PREAI
errForina, M.; Lanteri, S.; Casale, A.
errShare
errSave
Incremental and decremental active learning for optimized self-adaptive calibration in viscose production
err2014-11-01
err20
PREAI
errCernuda, Carlos; Lughofer, Edwin; Mayr, Georg; Roeder, Thomas; Hintenaus, Peter; Maerzinger, Wolfgang; Kasberger, Juergen
errShare
errSave
Evolving chemometric models for predicting dynamic process parameters in viscose production
err2012-05-01
err13
PREAI
errCernuda, Carlos; Lughofer, Edwin; Suppan, Lisbeth; Roeder, Thomas; Schmuck, Roman; Hintenaus, Peter; Maerzinger, Wolfgang; Kasberger, Juergen
errShare
errSave
researcher View more