Aortic valve imaging using 18F-sodium fluoride: impact of triple motion correction

delete2022-01-29
delete4
delete
OA
AI
M
Martin Lyngby Lassen
E
Evangelos Tzolos
D
Daniele Massera
S
Sebastien Cadet
R
Rong Bing
J
Jacek Kwieciński
D
Damini Dey
D
Daniel S. Berman
M
Marc R. Dweck
D
David E. Newby
P
Piotr J. Slomka *
DOI:10.1186/s40658-022-00433-7delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Background: Current F-18-NaF assessments of aortic valve microcalcification using F-18-NaF PET/CT are based on evaluations of end-diastolic or cardiac motion-corrected (ECG-MC) images, which are affected by both patient and respiratory motion. We aimed to test the impact of employing a triple motion correction technique (3 x MC), including cardiorespiratory and gross patient motion, on quantitative and qualitative measurements. Materials and methods: Fourteen patients with aortic stenosis underwent two repeat 30-min PET aortic valve scans within (29 +/- 24) days. We considered three different image reconstruction protocols; an end-diastolic reconstruction protocol (standard) utilizing 25% of the acquired data, an ECG-gated (four ECG gates) reconstruction (ECG-MC), and a triple motion-corrected (3 x MC) dataset which corrects for both cardiorespiratory and patient motion. All datasets were compared to aortic valve calcification scores (AVCS), using the Agatston method, obtained from CT scans using correlation plots. We report SUVmax values measured in the aortic valve and maximum target-to-background ratios (TBRmax) values after correcting for blood pool activity. Results: Compared to standard and ECG-MC reconstructions, increases in both SUVmax and TBRmax were observed following 3 x MC (SUVmax: Standard = 2.8 +/- 0.7, ECG-MC = 2.6 +/- 0.6, and 3 x MC = 3.3 +/- 0.9; TBRmax: Standard = 2.7 +/- 0.7, ECG-MC = 2.5 +/- 0.6, and 3 x MC = 3.3 +/- 1.2, all p values <= 0.05). 3 x MC had improved correlations (R-2 value) to the AVCS when compared to the standard methods (SUVmax: Standard = 0.10, ECG-MC = 0.10, and 3 x MC = 0.20; TBRmax: Standard = 0.20, ECG-MC = 0.28, and 3 x MC = 0.46). Conclusion: 3 x MC improves the correlation between the AVCS and SUVmax and TBRmax and should be considered in PET studies of aortic valves using F-18-NaF.
Keywords:
Motion correction
PET/CT
Cardiac PET
F-18-sodium fluoride
Aortic valve imaging
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

EJNMMI Physics cover
EJNMMI Physics
IF:
3.2
Papers:
774
Citations:
1.8K

Organization

C
Copenhagen University Hospital
Scholars:
1.2W
Papers: 9.2K
Citations: 1.6W
U
University of Copenhagen
Scholars:
7.6W
Papers: 6.6W
Citations: 86
R
Rigshospitalet
Scholars:
1.7W
Papers: 1.3W
Citations: 2.1W
C
Cedars Sinai Medical Center
Scholars:
1.3W
Papers: 1.1W
Citations: 23
researcher View more organizations