Automated beam placement for breast radiotherapy using a support vector machine based algorithm

delete2012-04-16
delete22
PRE
AI
X
Xuan Zhao
D
Dewen Kong
G
Gabor Jozsef
J
Jenghwa Chang
E
Edward K. Wong
S
Silvia C. Formenti
Y
Yao Wang *
DOI:10.1118/1.3700736delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Purpose: To develop an automated beam placement technique for whole breast radiotherapy using tangential beams. We seek to find optimal parameters for tangential beams to cover the whole ipsilateral breast (WB) and minimize the dose to the organs at risk (OARs). Methods: A support vector machine (SVM) based method is proposed to determine the optimal posterior plane of the tangential beams. Relative significances of including/avoiding the volumes of interests are incorporated into the cost function of the SVM. After finding the optimal 3-D plane that separates the whole breast (WB) and the included clinical target volumes (CTVs) from the OARs, the gantry angle, collimator angle, and posterior jaw size of the tangential beams are derived from the separating plane equation. Dosimetric measures of the treatment plans determined by the automated method are compared with those obtained by applying manual beam placement by the physicians. The method can be further extended to use multileaf collimator (MLC) blocking by optimizing posterior MLC positions. Results: The plans for 36 patients (23 prone- and 13 supine-treated) with left breast cancer were analyzed. Our algorithm reduced the volume of the heart that receives > 500 cGy dose (V5) from 2.7 to 1.7 cm(3) (p = 0.058) on average and the volume of the ipsilateral lung that receives > 1000 cGy dose (V10) from 55.2 to 40.7 cm(3) (p = 0.0013). The dose coverage as measured by volume receiving > 95% of the prescription dose (V95%) of the WB without a 5 mm superficial layer decreases by only 0.74% (p = 0.0002) and the V95% for the tumor bed with 1.5 cm margin remains unchanged. Conclusions: This study has demonstrated the feasibility of using a SVM-based algorithm to determine optimal beam placement without a physician's intervention. The proposed method reduced the dose to OARs, especially for supine treated patients, without any relevant degradation of dose homogeneity and coverage in general. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3700736]
Keywords:
breast radiotherapy
automated beam placement
support vector machines
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Medical Physics cover
Medical Physics
IF:
3.2
Papers:
3.7W
Citations:
3.2W

Organization

N
New York University
Scholars:
4.4W
Papers: 3.9W
Citations: 5.8W
N
New York University Tandon School of Engineering
Scholars:
1.1K
Papers: 847
Citations: 0