arrow
Return

Automatic collateral quantification in acute ischemic stroke using U2-net

delete2025-05-12
delete0
delete
OA
AI
Q
Qingqing Lu
H
Hongyi Chen
J
Junyan Fu
郑
郑小东 (Xiaodong Zheng)
Y
Yiren Xu
Y
Yuning Pan *
DOI:10.3389/fneur.2025.1502382delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Objectives: To harness the U-2-Net deep learning framework for automated quantification of collateral circulation in acute ischemic stroke (AIS) via computed tomography angiography (CTA) images, comparing its performance against traditional visual collateral scores (vCS). Methods: A cohort of 118 confirmed AIS cases was assembled and stratified into 94 development and 24 test cases. CTA images underwent preprocessing and annotation. The U-2-Net was trained to segment collateral vessels, yielding a quantitative collateral score (qCS) based on vessel volume ratios between affected and healthy hemispheres. Performance was assessed via Dice Similarity Coefficient (DSC), Spearman correlation, Intraclass Correlation Coefficient (ICC), and accuracy, with comparisons to vCS (Tan and Menon score) and ground truth. Result: The U-2-Net demonstrated robust segmentation capabilities, achieving a mean DSC of 0.75 in the test set. The qCS showed a strong correlation with vCS with rho ranging from 0.78 to 0.92. When compared to the more refined six-class Menon score, the qCS exhibited stronger consistency (development set: ICC = 0.83, test set: ICC = 0.93) than when compared to the four-class Tan score (development set: ICC = 0.76, test set: ICC = 0.79). In terms of classification accuracy, the AI model achieved 0.83 and 0.71 against ground truth and vCS, respectively, for four-class classification. This accuracy escalated to 0.88 and 0.83 for binary classification, emphasizing its proficiency in differentiating collateral status. Conclusion: Our U-2-Net AI model offers a reliable, objective tool for quantifying collateral circulation in AIS. The qCS aligns well with vCS and demonstrates the feasibility of automated collateral assessment, which may enhance diagnostic accuracy and therapeutic decision-making.
Keywords:
quantitative collateral score
visual collateral score
acute ischemic stroke
deep learning
U-2-Net

Journal

Frontiers in Neurology cover
Frontiers in Neurology
IF:
2.8
Papers:
4.6K
Citations:
4.7W

Organization

No organization information available
Cited Papers

Cited Papers

Inter-rater reliability for assessing intracranial collaterals in patients with acute ischemic stroke: comparing 29 raters and an artificial intelligence-based software
err2022-05-24
err0
errOAAI
errLennard Wolff; Jiahang Su; Derek Van Loon; Adriaan van Es; Pieter Jan van Doormaal; Charles Majoie; Wim van Zwam; Diederik Dippel; Aad van der Lugt; Theo van Walsum
errShare
errSave
Observer reliability of CT angiography in the assessment of acute ischaemic stroke: data from the Third International Stroke Trial
err2014-10-07
err0
errOAAI
errGrant Mair; Rüdiger von Kummer; Alessandro Adami; Philip M. White; Matthew E. Adams; Bernard Yan; Andrew M. Demchuk; Andrew J. Farrall; Robin J. Sellar; Rajesh Ramaswamy; Daisy Mollison; Elena V. Boyd; Mark A. Rodrigues; Karim Samji; Andrew J. Baird; Geoff Cohen; Eleni Sakka; Jeb Palmer; David Perry; Richard Lindley; Peter A. G. Sandercock; Joanna M. Wardlaw
errShare
errSave
Value of Quantitative Collateral Scoring on CT Angiography in Patients with Acute Ischemic Stroke
err2018-04-19
err43
errOAAI
errBoers, A. M. M.; Sales Barros, R.; Jansen, I. G. H.; Berkhemer, O. A.; Beenen, L. F. M.; Menon, B. K.; Dippel, D. W. J.; van der Lugt, A.; van Zwam, W. H.; Roos, Y. B. W. E. M.; van Oostenbrugge, R. J.; Slump, C. H.; Majoie, C. B. L. M.; Marquering, H. A.
errShare
errSave
Systematic comparison of perfusion-CT and CT-angiography in acute stroke patients
err2007-04-12
err321
PREAI
errTan, Jessica C.; Dillon, William P.; Liu, Songling; Adler, Felix; Smith, Wade S.; Wintermark, Max
errShare
errSave
Automated Collateral Flow Assessment in Patients with Acute Ischemic Stroke Using Computed Tomography with Artificial Intelligence Algorithms
err2021-11-01
err0
PREAI
errRyan A. Rava; Samantha E. Seymour; Kenneth V. Snyder; Muhammad Waqas; Jason M. Davies; Elad I. Levy; Adnan H. Siddiqui; Ciprian N. Ionita
errShare
errSave
Collateral Circulation in Thrombectomy for Stroke After 6 to 24 Hours in the DAWN Trial
errSTROKE
IF8.9
err2022-03-01
err72
errOAAI
errLiebeskind, David S.; Saber, Hamidreza; Xiang, Bin; Jadhav, Ashutosh P.; Jovin, Tudor G.; Haussen, Diogo C.; Budzik, Ronald F.; Bonafe, Alain; Bhuva, Parita; Yavagal, Dileep R.; Hanel, Ricardo A.; Ribo, Marc; Cognard, Christophe; Sila, Cathy; Hassan, Ameer E.; Smith, Wade S.; Saver, Jeffrey L.; Nogueira, Raul G.
errShare
errSave
Artificial Intelligence for Clinical Decision Support in Acute Ischemic Stroke: A Systematic Review
errSTROKE
IF8.9
err2023-06-01
err12
errOAAI
errAkay, Ela Marie Z.; Hilbert, Adam; Carlisle, Benjamin G.; Madai, Vince I.; Mutke, Matthias A.; Frey, Dietmar
errShare
errSave
Deep learning for collateral evaluation in ischemic stroke with imbalanced data
err2023-01-12
err0
PREAI
errMumu Aktar; Jonatan Reyes; Donatella Tampieri; Hassan Rivaz; Yiming Xiao; Marta Kersten-Oertel
errShare
errSave
Diagnostic performance of an algorithm for automated collateral scoring on computed tomography angiography
err2022-03-04
err0
errOAAI
errLennard Wolff; Simone M. Uniken Venema; Sven P. R. Luijten; Jeannette Hofmeijer; Jasper M. Martens; Marie Louise E. Bernsen; Adriaan C. G. M. van Es; Pieter Jan van Doormaal; Diederik W. J. Dippel; Wim van Zwam; Theo van Walsum; Aad van der Lugt
errShare
errSave
researcher View more