arrow
Return

Automatic Optical Path Alignment Method for Optical Biological Microscope

delete2024-12-27
delete0
delete
OA
AI
G
Guojin Peng
Z
Zhenming Yu *
X
Xinjian Zhou
G
Guangyao Pang
K
Kuikui Wang
DOI:10.3390/s25010102delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
A high-quality optical path alignment is essential for achieving superior image quality in optical biological microscope (OBM) systems. The traditional automatic alignment methods for OBMs rely heavily on complex masker-detection techniques. This paper introduces an innovative, image-sensor-based optical path alignment approach designed for low-power objective (specifically 4x) automatic OBMs. The proposed method encompasses reference objective (RO) identification and alignment processes. For identification, a model depicting spot movement with objective rotation near the optical axis is developed, elucidating the influence of optical path parameters on spot characteristics. This insight leads to the proposal of an RO identification method utilizing an edge gradient and edge position probability. In the alignment phase, a symmetry-based weight distribution scheme for concentric arcs is introduced. A significant observation is that the received energy stabilizes with improved alignment precision, prompting the design of an advanced alignment evaluation method that surpasses conventional energy-based assessments. The experimental results confirm that the proposed RO identification method can effectively differentiate between 4x and 10x objectives across diverse light intensities and exposure levels, with a significant numerical difference of up to 100. The error-radius ratio of the weighted circular fitting method is maintained below 1.16%, and the fine alignment stage's evaluation curve is notably sharper. Moreover, tests under various imaging conditions in artificially saturated environments indicate that the alignment estimation method, predicated on critical saturation positions, achieves an average error of 0.875 pixels.
Keywords:
biological microscope
optical path alignment
objective identification
weighted circle fitting
alignment evaluation
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Sensors cover
Sensors
IF:
3.5
Papers:
7.1W
Citations:
20.9W

Organization

W
Wuzhou University
Scholars:
312
Papers: 308
Citations: 454
G
Guilin University of Electronic Technology
Scholars:
7.4K
Papers: 5.2K
Citations: 5.4K