1
Return

Bilateral Total Knee Arthroplasties Performed With and Without Computer Navigation: Prospective 11-Year Postoperative Evaluation

delete2026-04-01
delete0
PRE
AI
K
Knee, Primary
B
Behun, Michael A.
S
Salimi, Maryam
B
Bryman, Jason A.
J
Johnson, Roseann M.
V
Vyge, Olivia P.
J
Jennings, Jason M.
D
Dennis, Douglas A. *
DOI:10.1016/j.arth.2025.08.046delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Background: Computer navigation has been used in total knee arthroplasty in an attempt to improve component alignment and clinical outcomes, although few studies directly compare computer navigation to traditional instrumentation in the same patient. Methods: Bilateral total knee arthroplasties performed during the same surgical intervention utilizing computer navigation in one knee and traditional instrumentation in the contralateral knee were prospectively collected and followed. Reoperations and adverse events were documented. Statistical analyses were performed between the two groups to determine differences in clinical outcomes. Results: There were 79 patients who had a mean follow-up of 11.8 years (range, five to 16). When comparing computer navigation to traditional instrumentation cohorts, mean postoperative femoral component coronal angle (94.9 versus 94.9 degrees , P = 0.88), femoral component flexion (2.1 versus 1.8 degrees , P = 0.53), tibial component coronal angle (89.7 versus 90 degrees , P = 0.24), and posterior tibial slope (2.4 versus 2.9 degrees , P = 0.15) showed no statistical differences. Computer navigation demonstrated a decrease in posterior tibial slope outliers (1 versus 8, P = 0.018) compared to traditional instrumentation, but no differences in the other component angles. Clinically, there were no differences in mean postoperative extension (0.2 versus 0.2 degrees , P = 0.97), flexion (127.3 versus 127.1 degrees , P = 0.85), functional Knee Society Scores (91.3 versus 90.5, P = 0.77), reoperation rate (6.3 versus 2.5%, P = 0.44), or closed manipulation rate (2.5 versus 3.8%, P = 0.65) at final follow-up comparing computer navigation to traditional instrumentation, respectively. Computer navigation reoperation indications included two patellar osteolysis, one infection, one patellar clunk syndrome, and one symptomatic arthrotomy nonabsorbent suture removal. Traditional instrumentation reoperation indications included one infection and one arthrotomy dehiscence. Conclusions: Computer navigation reduced posterior tibial slope outliers, although this did not translate to any appreciable difference in clinical outcome at 11 years' mean follow-up in the hands of a fellowship-trained total joint specialist. (c) 2025 Elsevier Inc. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
Keywords:
computer navigation
bilateral
total knee arthroplasty
clinical outcomes
radiographic alignment

Journal

JOURNAL OF ARTHROPLASTY cover
JOURNAL OF ARTHROPLASTY
IF:
3.8
Papers:
1.2W
Citations:
3.0W

Organization

A
adventist health services
Scholars:
2.1K
Papers: 1.7K
Citations: 0
A
AdventHealth
Scholars:
1.5K
Papers: 1.2K
Citations: 41
Cited Papers

Cited Papers

Citing Papers

Citing Papers