En 中文
Existing bollard force measurement methods have not yet been able to realise simple, accurate, and efficient measurements of the bollard force of a single ship's cable. In this paper, an experimental study on the measurement of ship bollard force is carried out with reference to the calculation method of measuring the cable force of a diagonal cable. Based on the fundamental frequency method and the frequency difference method, a new comprehensive method is proposed to detect the fundamental frequency of cable vibration. A study on the identification of the cable condition based on the measured vibration data is also carried out. Experimental studies on the error rate of different data acquisition positions, excitation methods, excitation positions, wetted cables, different temperatures, and other influencing factors were conducted, and a new excitation method based on environmental excitation and artificial excitation was proposed. By analysing the calculated values of the vibration frequency method and the tensile values of the prototype test platform, it is concluded that the data acquisition position, excitation position, and excitation method have a small influence on the measured value of the ship's bollard force, and the range of the error rate increases by about 1.5% under the wetting of the cable and +/- 2% under the low temperature (2 degrees C), with the integrated error range of -5% to 4%, and the error rate can satisfy the normal distribution well, and the measurement accuracy is corrected by correcting the length of the cable. The measurement accuracy is corrected by correcting the cable length. It is proved that the method has strong feasibility and applicability, and can effectively realise simple, accurate, and efficient measurement of ship bollard force.
Keywords:
frequency method
cable force
measurement accuracy
error analysis

Journal

W
Water
IF:
3
Papers:
3.2W
Citations:
7.4W

Organization

Cited Papers

Cited Papers

Experimental evaluation of the tension mooring effect on the response of moored ships
err2014-03-01
err47
PREAI
errRosa-Santos, Paulo; Taveira-Pinto, Francisco; Veloso-Gomes, Fernando
errShare
errSave
errShare
errSave
A REVIEW OF SHIP MOORING SYSTEMS
err2017-10-01
err26
errOAAI
errVilla-Caro, R.; Carral, J. C.; Fraguela, J. A.; Lopez, M.; Carral, L.
errShare
errSave
errShare
errSave
researcher View more