Return
Bond strength of resin cement to multilayer graded zirconia after saliva and blood contamination with different cleaning protocols
J
B
P
S
J
M
B
R
DOI:10.1016/j.ijadhadh.2026.104353.png)
Abstract
En 中文
To evaluate the bond strength of resin cement to multilayer graded zirconia contaminated with human saliva or blood after different cleaning protocols and aging. Multilayer graded zirconia specimens (3Y-TZP and 5Y-PSZ; IPS e.max ZirCAD Prime) were allocated into 16 groups according to factors: “contamination” (saliva or blood), “cleaning method” (no cleaning, water rinsing, Ivoclean, or airborne-particle abrasion), and “aging condition” (10,000 thermocycles or 24-h storage). Resin cement cylinders were bonded to each specimen (n = 15/group), and shear bond strength (SBS) was tested at 1.0 mm/min. Failure modes were analyzed, and representative surfaces were examined by energy-dispersive X-ray spectroscopy. SBS data were analyzed using two-way ANOVA, Tukey's HSD test (α = 0.05), and Weibull analysis.
Keywords:
resin cement
multilayer graded zirconia
saliva contamination
blood contamination
cleaning protocols
Journal
IF:
3.5
Papers:
3.8K
Citations:
9.6K