arrow
Return

CFD-based flow characterization and pre-investigation-guided measurement optimization for large-diameter stacks with complex upstream structures

delete2026-04-21
delete0
PRE
AI
X
Xuejun Tian
Z
Zhimin Lü *
Z
Zili Xie
Z
Zeming Liu
X
Xiaolong Li
G
Guimin Li
J
Jian Yang
S
Shunchun Yao *
DOI:10.1016/j.measurement.2026.121586delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
• Proposed a framework for stack flow characterization and measurement optimization. • Complex ducts induced backflow, swirling, asymmetric flow and large flow angles. • CFD pre-investigation-guided 8-point Pitot scheme achieved errors of 0.76%-1.12%. • Four-path ultrasonic flowmeter yielded errors < 0.4% in complex flow fields.