Return
Characterisation tools development for PEM electrolysers
DOI:10.1016/j.ijhydene.2014.02.096.png)
Abstract
En 中文
Electrochemical impedance spectroscopy (EIS), current interrupt (CI) and current mapping (CM) were investigated as in-situ characterisation tools for PEM electrolysers. A 25 cm(2) cell with titanium anode and carbon cathode plates were utilised in this study. A commercial MEA consisting of 1 mg IrO2/cm(2) on the anode and 0.3 mg Pt/cm(2) on the cathode was used. The electrocatalyst was deposited on Nafion (R) membranes. The electrochemical losses in a PEM electrolyser namely: activation, ohmic and mass transfer losses were identified using EIS and CI and both the advantages and disadvantages of the methods were discussed. The current distribution over the membrane electrode assembly (MEA) at different current densities was measured using the current mapping method. It is also shown that under the given experimental conditions the current density decreases along the serpentine flow field. Copyright (C) 2014, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
Keywords:
Hydrogen
Electrochemical impedance spectroscopy (EIS)
Current interrupt (CI)
Current mapping (CM)
Proton exchange membrane (PEM)
Electrolyser
AI Summary
Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.
Journal
IF:
8.3
Papers:
5.5W
Citations:
23.1W
Organization
Cited Papers
Energetic evaluation of high pressure PEM electrolyzer systems for intermediate storage of renewable energies
ELECTROCHIMICA ACTA
IF5.6